YASKAWA CIMR-VU BA0001 Technical Manual page 369

Ac drive-v1000 200 v class, three-phase input: 0.1 to 18.5 kw; 200 v class, single-phase input: 0.1 to 3.7 kw; 400 v class, three-phase input: 0.2 to 18.5 kw
Table of Contents

Advertisement

No.
Name
Motor 2 Max Output
E3-04
Frequency
E3-05
Motor 2 Max
<1>
Voltage
Motor 2 Base
E3-06
Frequency
Motor 2 Mid Output
E3-07
Freq.
E3-08
Motor 2 Mid Output
<1>
Freq. Voltage
Motor 2 Min. Output
E3-09
Freq.
E3-10
Motor 2 Min. Output
<1>
Freq. Voltage
E3-11
Motor 2 Mid Output
<7>
Frequency 2
E3-12
Motor 2 Mid Output
<1>
Frequency Voltage
2
<13>
E3-13
Motor 2 Base
<1>
Voltage
<9>
Motor 2 Rated
E4-01
Current
Motor 2 Rated Slip Sets the motor 2 rated slip in Hz. Automatically set during
E4-02
Motor 2 Rated No-
E4-03
Load Current
Motor 2 Motor Poles Sets the number of poles of motor 2. This value is
E4-04
Motor 2 Line-to-
E4-05
Line Resistance
Motor 2 Leakage
E4-06
Inductance
Motor 2 Motor Iron-
E4-07
Core Saturation
Coefficient 1
Motor 2 Motor Iron-
E4-08
Core Saturation
Coefficient 2
Motor 2 Mechanical
E4-09
Loss
E4-10
Motor 2 Iron Loss
Motor 2 Rated
E4-11
Capacity
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
Description
To set linear V/f characteristics, set the same values for
E3-07 and E3-09. In this case, the setting for E3-08 will be
disregarded.
Ensure that the five frequencies are set according to these
rules to prevent triggering an oPE10 fault:
E3-09 ≤ E3-07 < E3-06 ≤ Ε3−11 ≤ E3-04
Note: Setting E3-11 to 0 disables both E3-11 and E3-12, and
the above conditions do not apply.
VACrms Out (V)
E3-05
E3-12
E3-13
E3-08
E3-10
E3-09 E3-07
Frequency (Hz)
E4: Motor 2 Parameters
Use E4 parameters to control a second motor operating on the same drive.
Sets the motor 2 nameplate full load current in amperes (A).
This value is automatically set during Auto-Tuning.
Auto-Tuning.
Sets the magnetizing current of motor 2 in Ampere.
Automatically set during Rotational Auto-Tuning.
automatically set during Auto-Tuning.
Sets the phase-to-phase resistance of motor 2 in ohms.
Automatically during Auto-Tuning.
Sets the voltage drop due to motor leakage inductance as a
percentage of rated voltage of motor 2. Automatically set
during Auto-Tuning.
Set to the motor iron saturation coefficient at 50% of
magnetic flux. Automatically set during Rotational
Auto-Tuning.
Set to the motor iron saturation coefficient at 75% of
magnetic flux. This value is automatically set during
Rotational Auto-Tuning.
Sets the motor mechanical loss as a percentage of motor rated
power (kW) capacity.
Adjust in the following circumstances:
• When there is a large amount of torque loss due to motor
bearing friction.
• When there is a large amount of torque loss.
Sets the motor iron loss in watts.
Sets the motor rated capacity in kW. Automatically set
during Auto-Tuning.
Range
40.0 to
400.0
0.0 to 255.0 230.0 V
0.0 to
E3-04
0.0 to
E3-04
0.0 to 255.0
0.0 to
E3-04
0.0 to 255.0
0.0 to
E3-04
E3-06 E3-11 E3-04
0.0 to 255.0
0.0 to 255.0
10 to 200%
of drive
rated
current
0.00 to
20.00
0 to less
than E4-01
2 to 48
0.000 to
65.000
<11>
0.0 to 40.0
0.00 to 0.50
Setting for
E4-07 to
0.75
0.00 to 10.0
0 to 65535
0.00 to
650.00
B.2 Parameter Table
Control
Mode
Def.
V/f O
PM
LV
60 Hz
A
A
A
A
60 Hz
A
A
3.0 Hz
A
A
<12>
18.4 V
<6>
A
A
<12>
1.5 Hz
A
A
<12>
13.8 V
<6>
A
A
<12>
0.0 Hz
A
A
0.0 Vac
A
A
<1>
0.0 Vac
A
S
<1>
<10>
A
A
<10>
A
A
<10>
A
A
<9>
4 poles
A
A
<10>
A
A
<10>
A
A
0.50
A
0.75
A
0.0
A
<10>
Α
<6>
A
A
Addr. Hex Pg.
31A
175
31B
175
31C
175
31D
175
31E
175
31F
175
320
175
345
175
346
175
347
175
321
176
322
176
323
176
324
176
325
176
326
176
343
177
344
177
33F
177
B
340
177
327
177
369