C.10 MEMOBUS/Modbus Data Table
Register No.
Drive status (U1-12)
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
004BH
bit 6
bit 7
bit 8
bit 9
bit A
bit B to D
bit E
bit F
004CH to 007EH
Used for various monitors U1-oo, U4-oo, U5-oo and U6-oo.
007FH
Alarm Code,
Used for monitors U2-oo, U3-oo.
0080H to 0097H
Contents on page 457
U4-01 (Cumulative Operation Time)
0098H, 0099H
Example: When U4-01 (Cumulative Operation Time) is 12345 hours, then 0098H = 1234 and 0099H = 5.
U4-03 (Cooling Fan Operation Time)
009AH, 009BH
Example: When U4-03 (Cooling Fan Operation Time) is 12345 hours, then 009AH = 1234 and 009BH = 5.
00ABH
Drive Rated Current
00ACH
Motor Speed (Open Loop
Vector only)
00ADH
00AEH, 00AFH
Reserved
00B0H
Option Code
00B1H to 00B4H
Reserved
00B5H
Frequency Reference After
Soft-starter
00B6H
00B7H
Frequency Reference
00B8H
00BFH
oPE Error Number
452
During Run
During Zero Speed
During Reverse Run
During Fault Reset Signal Input
During Speed Agree
Drive Ready
Alarm
Fault
During Operation Error (oPEoo)
During Momentary Power Loss
Motor 2 selected
Reserved
ComRef status, NetRef status
ComCtrl status, NetCtrl status
Refer to Alarm Register Contents on page 458
Refer to U: Monitors on page 399
for register value descriptions.
<2>
<4>
r/min units
0.01% units
The following lists the 3 and 4 letter ASCII codes stored for each serial communication option:
CANopen (Model: SI-S3/V): 5353H
CC-Link (Model: SI-C3/V): 5343H
DeviceNet (Model: SI-N3/V): 534EH
PROFIBUS-DP (Model: SI-P3/V): 5350H
MECHATROLINK-II (Model: SI-T3/V): 5354H
MECHATROLINK-III (Model: SI-ET3/V): 1004H
CompoNet (Model: SI-M3/V): 434EH
Other options use their own unique codes. Refer to the communication option instruction manual
for the option code.
<4>
r/min units
0.01% units
<4>
r/min
0.01% units
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual