YASKAWA CIMR-VU BA0001 Technical Manual page 383

Ac drive-v1000 200 v class, three-phase input: 0.1 to 18.5 kw; 200 v class, single-phase input: 0.1 to 3.7 kw; 400 v class, three-phase input: 0.2 to 18.5 kw
Table of Contents

Advertisement

No.
Name
Stopping Method After
H5-04
Communication Error
Communication Fault
H5-05
Detection Selection
H5-06
Drive Transmit Wait Time
H5-07
RTS Control Selection
H5-09
CE Detection Time
Unit Selection for
H5-10
MEMOBUS/Modbus
Register 0025H
Communications ENTER
H5-11
Function Selection
Run Command Method
H5-12
Selection
Pulse Train Input Terminal
H6-01
RP Function Selection
H6-02
Pulse Train Input Scaling
<2>
H6-03
Pulse Train Input Gain
<2>
H6-04
Pulse Train Input Bias
<2>
H6-05
Pulse Train Input Filter
<2>
Time
H6-06
Pulse Train Monitor Terminal
<2>
MP Selection
H6-07
Pulse Train Monitor Scaling
<2>
<1> The availability of certain functions depends on the control method used.
<2> Parameter can be changed during Run.
<3> If this parameter is set to 0, the drive will be unable to respond to MEMOBUS/Modbus commands.
<4> Default setting is determined by drive software version.
PRG: 1016 and later: 100 to 32000 Hz
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
Description
Selects the stopping method when a communication time-out
fault (CE) is detected.
0: Ramp to stop
1: Coast to stop
2: Fast-stop
3: Alarm only
Enables or disables the communications time-out fault (CE)
detection.
0: Disabled
1: Enabled - If communication is lost for more than two
seconds, a CE fault will occur.
Set the wait time between receiving and sending data.
Selects "request to send" (RTS) control:
0: Disabled - RTS is always on.
1: Enabled - RTS turns on only when sending.
Sets the time required to detect a communications error.
Adjustment may be need when networking several drives.
Selects the units used for MEMOBUS/Modbus register
0025H (Output Voltage Reference Monitor).
0: 0.1 V units
1: 1 V units
Select the function for the enter command that saves
parameter data to the drive.
0: Parameter changes are activated when ENTER command
is entered.
1: Parameter changes are activated immediately without
ENTER command (compatible with Varispeed VS606-V7).
0: FWD/STOP, REV/STOP Method
1: RUN/STOP, FWD/REV Method
H6: Pulse Train Input/Output
Use H6 parameters to configure Pulse Train I/O operation.
Selects pulse train input function.
0: Frequency reference
1: PID feedback value
2: PID setpoint value
3: V/f Control with Simple PG Feedback (can be set only when
using motor 1 in V/f Control)
Sets the terminal RP input signal frequency that is equal to
100% of the value selected in H6-01.
Sets the level of the value selected in H6-01 when a frequency
with the value set in H6-02 is input.
Sets the level of the value selected in H6-01 when 0 Hz is
input.
Sets the pulse train input filter time constant.
Select the pulse train monitor output function (value of the
o-oo part of Uo-oo).
Refer to U: Monitors on page 399
Example: To select U5-01, set "501. "When not using this
parameter or when using in the through mode, set "000".
<5>
Sets the terminal MP output signal frequency when the
monitor value is 100%. Set H6-06 to 102 and H6-07 to 0 to
make the pulse train monitor output equal to the output
frequency.
Range
0 to 3
0, 1
5 to 65
0, 1
0.0 to 10.0
s
0, 1
0, 1
0, 1
0 to 3
<4>
0.0 to
1000.0
-100.0 to
+100.0
0.00 to
2.00
000, 031,
101, 102,
for the list of U monitors.
105, 116,
501, 502;
801 to 809
0 to 32000
B.2 Parameter Table
Control
Mode
Addr.
Def.
Pg.
O
Hex
V/
P
L
f
M
V
3
A A A
428
439
1
A A A
429
440
5 ms A A A
42A
440
1
A A A
42B
440
2.0 s A A A
435
440
0
A A A
436
440
1
A A A
43C
441
0
A A A
43D
441
0
A A A
42C
211
1440
A A A
42D
211
Hz
100.0
A A A
42E
211
%
0.0% A A A
42F
211
0.10 s A A A
430
211
102
A A A
431
212
1440
A A A
432
212
Hz
383
B