8.6 Device Range that Can Be Set

The device ranges of controller that can be used for GOT
are as follows.
Note that the device ranges in the following tables are the
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ
depending on the models, even though belonging to the
same series.
Please make the setting according to the specifications of
the controller actually used.
When a non-existent device or a device number outside
the range is set, other objects with correct device settings
may not be monitored.
Setting item
Item
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of
word device.
Device
Sets the number of the program for which
Program No.
the device is set.
Displays the device type and setting range which are
Information
selected in [Device].
Set the monitor target of the set device.
Network
Set this item when monitoring the PLC of
Station No.
the specified station No. (octal)
POINT
POINT
POINT
Program number setting (when PC3JG, PC3J or
PC3JD is used)
Setting of a program number is allowed for the devices
indicated below.
Internal relay (M), keep relay (K), link relay (L), special
relay (V), edge detection (P), timer (T), counter (C),
data register (D), link register (R), special register (S),
current value register (N)
Description
8.6.1
JTEKT PLC
(JTEKT TOYOPUC-PLC)
Device name
*1
Input (X)
*1
Output (Y)
Link relay (L)
Internal relay (M)
Keep relay (K)
Edge detection (P)
*1
Timer (T)
*1
Counter (C)
Special relay (V)
*1
Extended input (EX)
*1
Extended output (EY)
Extended internal relay (EM)
Extended keep-relay (EK)
Extended special relay (EV)
*1
Extended timer (ET)
*1
Extended counter (EC)
Extended link relay (EL)
Extended edge detection (EP)
*1*3
Extended input 2 (GX)
*1*3
Extended output 2 (GY)
*3
Extended internal relay (GM)
Specified bits of the following
Word device bit
(Excluding EB and TCS)
Data register (D)
Link register (R)
Current value register (N)
Special register (S)
File register (B)
Extended present value
register (EN)
Extended setup value register
(H)
Extended special register (ES)
Extended data register (U)
Extended buffer register
EB08000 to EB0FFFF
*3
(EB)
EB18000 to EB1FFFF
*2
TCS0000 to TCS01FF
Setup value register (TCS)
Word of bit devices above
Converting bit devices into word
*1
Overlapped device designation of an input (X, EX, GX) and
an output (Y, EY, GY), or a timer (T, ET) and a counter (C,
EC) is not allowed.(Example: X0000 and Y0000, EX0000
and EY0000)
*2
To store a setting value of T (timer) or C (counter), use TCS.
Setting value of a timer and a counter is stored in TCS.
(TCS cannot be used if a timer or a counter is not in a
program.)
*3
GX, GY, GM and EB can be used only in the PC3JG
separate mode.
Access to GX, GY, GM and EB through a link module is not
possible.
8. CONNECTION TO JTEKT PLC
8.6 Device Range that Can Be Set
Device
No.
Setting range
represen
tation
X000 to X7FF
Y000 to Y7FF
L000 to L7FF
M000 to M7FF
K000 to K2FF
P000 to P1FF
T000 to T1FF
C000 to C1FF
V000 to V0FF
EX000 to EX7FF
EY000 to EY7FF
Hexadeci
EM0000 to EM1FFF
mal
EK000 to EKFFF
EV000 to EVFFF
ET000 to ET7FF
EC000 to EC7FF
EL0000 to EL1FFF
EP000 to EPFFF
GX0000 to GXFFFF
GY0000 to GYFFFF
GM0000 to GMFFFF
word devices
D0000 to D2FFF
R0000 to R07FF
N0000 to N01FF
S0000 to S03FF
B0000 to B1FFF
EN0000 to EN07FF
Hexadeci
H0000 to H07FF
mal
ES0000 to ES07FF
U0000 to U7FFF
EB00000 to EB07FFF
EB10000 to EB17FFF
8 - 19