5.6 Device Range that Can Be Set

The device ranges of controller that can be used for GOT
are as follows.
Note that the device ranges in the following tables are the
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ
depending on the models, even though belonging to the
same series.
Please make the setting according to the specifications of
the controller actually used.
When a non-existent device or a device number outside
the range is set, other objects with correct device settings
may not be monitored.
Setting item
Item
Set the device name, device number, and bit number.
Device
The bit number can be set only when specifying the bit of
word device.
Displays the device type and setting range which are
Information
selected in [Device].
Set the monitor target of the set device.
Select this item when writing data to all
temperature connected.
During monitoring, the temperature controller of
station No.0 is monitored.
All
(When writing the data in numerical input, the
data is written to all connected temperature
controllers during input, and the temperature
controller of station No. 0 is monitored during
other than input (displaying).)
Network
Select this item when monitoring the temperature
controller of the specified station No.
After selecting, set the station No. in the following
range.
0 to 99:
Station
No.
100 to 115:
*1
The following table shows the relation between station
numbers of the PLC and the GOT data register.
Station
GOT data register
No.
(GD)
100
GD10
101
GD11
:
:
114
GD24
115
GD25
Description
To monitor the temperature
controller of the specified station
No.
To specify the station No. of the
temperature controller to be
monitored by the value of GOT
*1
data register (GD).
Setting range
0 to 99
(If setting a value outside
the range above, a
device range error
occurs.)
5. CONNECTION TO OMRON TEMPERATURE CONTROLLER
POINT
POINT
POINT
Device settings of OMRON temperature controller
(1) When setting the (S)
Make settings for status by a channel number and
a bit position.
(2) When setting variable area (0), variable area (1)
and variable area (2)
Make setting for variable areas by a channel
number and address.
5.6.1
OMRON temperature
controller (OMRON
THERMAC/INPANEL NEO)
Device name
Setting range
S0000 to S0031
*1
Status (S)
S0100 to S0131
Operation command
A0000 to A000C
*2
(A)
Variable area 0
C00000 to C00006
*1*3
C00100 to C00106
(C0)
Variable area 1
C10000 to C1001C
*3
C10100 to C1011C
(C1)
Variable area 3
C30000 to C3003E
*3
C30100 to C3013E
(C3)
*1
Only reading is possible.
*2
Only writing is possible.
Numerical input cannot be used.
When writing, use [Word Set] of a data set switch.
*3
Only 32-bit (2-word) designation is allowed.

5.6 Device Range that Can Be Set

Bit position
Channel No.
Address
Channel No.
Device No.
representation
Decimal
Hexadecimal
Decimal +
Hexadecimal
5 - 15