6.4 Device Range that Can Be Set

The device ranges of controller that can be used for GOT
are as follows.
Note that the device ranges in the following tables are the
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ
depending on the models, even though belonging to the
same series.
Please make the setting according to the specifications of
the controller actually used.
When a non-existent device or a device number outside
the range is set, other objects with correct device settings
may not be monitored.
Setting item
Item
Set the device name, device number, and bit number.
Device
The bit number can be set only when specifying the bit of
word device.
Displays the device type and its setting range selected in
Information
[Device].
Set the station number of the controller to be monitored.
Host
Select this item for monitoring the host controller.
Select this item for monitoring other controllers.
Network
After selecting, set the station number of the
Other
controller to be monitored.
NWNo.: Set the network No.
Station No.: Set the station No.
POINT
POINT
POINT
Device settings of KEYENCE PLC
(1) Setting setting procedure for relays (...), internal
auxiliary relays (MR), latch relays (LR) and control
relays(CR).
Make settings for status by a channel number and
a bit position.
Description
Bit position
Channel No.
6.4.1
KV-700/1000/3000/5000
Device name
Relay (...)
Internal auxiliary relay (MR)
Latch relay (LR)
Control relay (CR)
*2
Link relay (B)
*2
Work relay (VB)
*1*2
Timer (Contact) (T)
*1*2
Counter (Contact) (C)
High-speed counter
comparator
*2*3*6
(Contact) (CTC)
Specified bit of the following word
extension data memory
Word device bit
extension data memory 2
*2*4
Timer (Current value) (TC)
*2*4
Timer (Set value) (TS)
Counter (Current value)
*2*4
(CC)
*2*4
Counter (Set value) (CS)
High-speed counter
*2*4
(Current value) (CTH)
High-speed counter
comparator
*2*4
(Set value) (CTC)
Data memory (DM)
Extension data memory (EM)
Extension data memory 2 (FM)
ZF000000 to ZF032767
ZF032768 to ZF065535
File register (ZF)
ZF065536 to ZF098303
ZF098304 to ZF131071
Link register (W)
Control memory (CM)
Temporary data memory (TM)
Work memory (VM)
*7
Index register (Z)
Index register (DZ)
*4*5
Digital trimmer (TRM)
Converting the following bit
Bit device word
*1
Monitoring or writing is not possible in the continuous device
designation mode.
*2
Monitoring by GOT is possible only when a device is used in
the sequence program.
*3
When writing, only the reset of the contact is possible.
*4
Only 32-bit (2-word) designation is allowed.
*5
Only reading is possible.
*6
Monitoring or writing to continuous devices is not possible.
*7
With KV-3000 and KV-5000, Z devices cannot be specified
as 32-bit (2 words) data.
Use DZ devices.
6. CONNECTION TO KEYENCE PLC

6.4 Device Range that Can Be Set

Device
No.
Setting range
represen
tation
..00000 to ..99915
MR00000 to MR99915
Decimal
LR00000 to LR99915
CR0000 to CR3915
B0000 to B3FFF
Hexadec
imal
VB0000 to VB3FFF
T0000 to T3999
C0000 to C3999
Decimal
CTC0 to CTC3
devices
data memory
-
file register
link register
TC0000 to TC3999
TS0000 to TS3999
CC0000 to CC3999
CS0000 to CS3999
CTH0 to CTH1
Decimal
CTC0 to CTC3
DM00000 to DM65534
EM00000 to EM65534
FM00000 to FM32767
Hexadec
W0000 to W3FFF
imal
CM00000 to CM11998
TM000 to TM511
VM00000 to VM59999
Decimal
Z1 to Z12
DZ01 to DZ12
TRM0 to TRM7
devices to words
relay
internal auxiliary relay
-
latch relay
control relay
link relay
work relay
6 - 19