TOSHIBA PLC
(TOSHIBA PROSEC T/V Series)
Device name
External input (X)
External output (Y)
*6
Internal relay (R)
*6
Special relay (S)
Link register relay (Z)
Link relay (L)
*1
Timer (Contact) (T)
*1
Counter (Contact) (C)
Specified bit of the following
*2*6
Word device bit
External input (XW)
External output (YW)
*5*7
Internal relay (RW)*
*7
Special relay (SW)
Link relay (LW)
Timer (Current value)
*1
(T)
Counter (Current value)
*1
(C)
Data register (D)
*3*5*7
Link register (W)
*4
File register (F)
PROSEC T Series
*1
The writing of the timer (contact)/(current value) and counter
(contact)/(current value) are executed after being read by the
GOT. Therefore, do not edit it in the sequence program
during this period.
*2
As bit specification of a word device is performed after the
GOT reads the value, do not change the value in the
sequence program during this period.
*3
When the mode switch on the CPU module is set to "P-
RUN", writing to D0000 through D4095 is disabled.
*4
Extension file register is not supported.
PROSEC V Series
*2
As bit specification of a word device is performed after the
GOT reads the value, do not change the value in the
sequence program during this period.
*5
RW0000 and D0000 indicate the data register in the same
region although they are shown in different notations.
*6
For bit data, the conversion from the address notation for the
TOSHIBA PLC to that for the GOT is shown as follows.
Address notation for TOSHIBA PLC ÷ 16=Word address
(Quotient)...Bit address (Remainder)
Address
notation
Address notation
for TOSHIBA
for GOT
PLC
S511F
S8191
(Decimal)
(Hexadecimal)
R4095F
R65535
(Decimal)
(Hexadecimal)
Device
No.
Setting range
represen
tation
X0000 to X511F
Y0000 to Y511F
R0000 to R4095F
Hexadec
imal
S0000 to S511F
Z0000 to Z999F
L0000 to L255F
T0 to T999
Decimal
C0 to C511
word devices
Data register
-
Link register
File register
XW0 to XW511
YW0 to YW511
RW0 to RW4095
SW0 to SW511
LW0 to LW255
T0 to T999
Decimal
C0 to C511
D0 to D8191
W0 to W2047
F0 to F32767
Conversion
8191÷16= 511...15
65535÷16= 4095...15
*7
For word data, the conversion from the address notation for
the TOSHIBA PLC to that for the GOT is shown as follows.
Communication
Address notation
format
for TOSHIBA PLC
16bit data
(Integer)
(Calculate the device
No. in 32-bit unit)
32bit data
(Real
(Calculate the device
number)
No. in 32-bit unit)
12. CONNECTION TO TOSHIBA PLC
12.3 Device Range that Can Be Set
Address
notation
for GOT
DW10
D10
DD10
D20
DF10
D20
12
12 - 11