Adjust Vertical Boresight - Christie D4K2560 User Manual

Hfr 3-chip dlp 4k projector
Hide thumbs Also See for D4K2560:
Table of Contents

Advertisement

1. Loosen the lens mount stabilization screw (D).
2. Loosen the horizontal lock screw (A).
3. Extend the lens focus (B) completely.
4. Adjust the Focus using the focus knob to retract the lens. Watch the image at the left edge of
the screen until it comes into focus. If the entire screen is in focus, proceed to step 7.
5. Continue retracting the lens.
a. If the right side of the image comes into focus before the lens is completely retracted,
adjust the horizontal boresight bolt (C) to balance the left and right edges.
6. If the right side of the image fails to focus, adjust the horizontal boresight bolt (C).When both
sides appear equally blurry, adjust the offsets to re-center the image.Repeat steps 1 to 5 until
both sides of the image are focused.
7. Tighten the lock screw (A) and the lens mount stabilization screw (D) to maintain the
adjustments.
8. Check the boresight again.
9. Unless proceeding to adjust vertical boresight, perform a lens calibration.
For more details, see

Adjust vertical boresight

Warning! Failure to comply with the following could result in death or serious injury.
When doing optical adjustments on an operating projector and the top lid is removed, everyone
within the immediate vicinity must wear safety glasses with side shields and Christie approved
protective safety clothing (P/N: 598900-95).
1. Focus the image at the top edge of the screen
D4K2560 User Manual
020-101076-04 Rev. 1 (01-2015)
C
Calibrate the lens motors
A
D
B
on page 65.
Adjust the Image
38