Starter Relay Inspection - Suzuki Intruder VZR1800 Service Manual

Hide thumbs Also See for Intruder VZR1800:
Table of Contents

Advertisement

10-18
ELECTRICAL SYSTEM
• Tighten the starter motor mounting lead wire bolts 5 and nut
6 to the specified torque.
, Starter motor mounting bolt: 6 N·m (0.6 kgf-m, 4.5 lb-ft)
Starter motor lead wire nut: 6 N·m (0.6 kgf-m, 4.5 lb-ft)

STARTER RELAY INSPECTION

• Remove the front seat. (!9-4)
• Remove the battery cover.
• Disconnect the battery - lead wire from the battery.
• Remove the starter relay cover 1.
• Disconnect the starter relay coupler 2, starter motor lead
wire 3 and battery lead wire 4.
• Remove the starter relay.
• Apply 12 V to A and B terminals and check for continuity
between the positive and negative terminals using the
multi-circuit tester. If the starter relay clicks and continuity is
found, the relay is ok.
" 09900-25008: Multi-circuit tester set
- Tester knob indication: Continuity test (.)
#
Do not apply battery voltage to the starter relay for
more than five seconds, since the relay coil may over-
heat and get damaged.
Measure the relay coil resistance between the terminals using
the multi-circuit tester. If the resistance is not within the specified
value, replace the starter relay with a new one.
" 09900-25008: Multi-circuit tester set
$ Starter relay resistance: 3 – 6 Ω

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vzr1800

Table of Contents