5-62
FI SYSTEM DIAGNOSIS
Step 1 (When indicating P1654-H:)
1) Turn the ignition switch OFF.
2) Remove the right air cleaner box. (#6-13)
3) Check the STP sensor coupler for loose or poor contacts.
If OK, then check the STP sensor lead wire continuity.
STP sensor lead wire coupler: Black
4) Disconnect the STP sensor coupler.
5) Check the continuity between Y/W wire A and Red wire B.
If the sound is not heard from the tester, the circuit condition
is OK.
6) Disconnect the ECM coupler. (#5-37)
7) Check the continuity between Y/W wire A and terminal J.
8) Also, check the continuity between B/Br wire C and terminal
S.
"
When using the multi-circuit tester, do not strongly
touch the terminal of the ECM coupler with a needle
pointed tester probe to prevent the terminal damage
or terminal bend.
$ STPS lead wire continuity: Continuity (()
! 09900-25008: Multi-circuit tester set
09900-25009: Needle pointed probe set
) Tester knob indication: Continuity test (()
Is the continuity OK?
YES
Go to Step 2.
NO
Y/W wire shorted to VCC, or B/Br wire open
9) After repairing the trouble, clear the DTC using SDS tool.
(#5-26)
1
1
1
(Black)
ECM coupler (Harness side)
(Gray)