Exhaust Pipe And Muffler; Removal - Suzuki Intruder VZR1800 Service Manual

Hide thumbs Also See for Intruder VZR1800:
Table of Contents

Advertisement

7-8
EXHAUST SYSTEM
Measure the position sensor output voltage at fully open posi-
tion.
% Position sensor output voltage
EXCV is fully open: 3.5
If the measured voltage is more than specification, adjust the
No.2 cable adjuster as follows:
• Set the EXCVA to adjustment position. (!7-2)
#
Adjusting the No. 2 cable with the EXCV fully opened
can damage the EXCVA. Be sure to adjust the No. 2
cable with the EXCV set in adjustment position.
• Turn out the No. 2 cable adjuster 1.
• Repeat the above procedure until the output voltage comes
within the specified value.
% Position sensor output voltage
EXCV is fully open: 3.5
• After adjusting the EXCV cables, perform 2nd step to confirm
C46 is not indicated.

EXHAUST PIPE AND MUFFLER

REMOVAL

• Remove the right frame cover. (!9-5)
• Remove the lower frame cover 1.
• Disconnect the EXCVA lead wire couplers 2.
output voltage
(+ Yellow – - B/Br)
output voltage
V
4.5 V
4.5 V