Malfunction Code And Defective Condition - Suzuki Intruder VZR1800 Service Manual

Hide thumbs Also See for Intruder VZR1800:
Table of Contents

Advertisement

5-28
FI SYSTEM DIAGNOSIS

MALFUNCTION CODE AND DEFECTIVE CONDITION

DETECTED
DTC No.
C00
NO FAULT
CKP sensor
C12
P0335
IAP sensor
C13/C17
P1750/P0105
H
P1750/
P0105
L
TP sensor
C14
P0120
H
P0120
L
ECT sensor
C15
P0115
H
P0115
L
IAT sensor
C21
P0110
H
P0110
L
DETECTED FAILURE CONDITION
ITEM
The signal does not reach ECM for 3
sec. or more, after receiving the starter
signal.
The sensor should produce following
voltage.
0.5 V
sensor voltage < 4.85 V
In other than the above range, C13
(P1750) or C17 (P0105) is indicated.
Sensor voltage is higher than specified
value.
Sensor voltage is lower than specified
value.
The sensor should produce following
voltage.
0.2 V
sensor voltage < 4.80 V
In other than the above range, C14
(P0120) is indicated.
Sensor voltage is higher than specified
value.
Sensor voltage is lower than specified
value.
The sensor voltage should be the fol-
lowing.
0.15 V
sensor voltage < 4.85 V
In other than the above range, C15
(P0115) is indicated.
Sensor voltage is higher than specified
value.
Sensor voltage is lower than specified
value.
The sensor voltage should be the fol-
lowing.
0.15 V
sensor voltage < 4.85 V
In other than the above range, C21
(P0110) is indicated.
Sensor voltage is higher than specified
value.
Sensor voltage is lower than specified
value.
–––––––––––
CHECK FOR
–––––––––––
CKP sensor wiring and mechan-
ical parts
CKP sensor, lead wire/coupler
connection
IAP sensor, lead wire/coupler
connection
IAP sensor circuit shorted to
VCC or ground circuit open
IAP sensor circuit open or
shorted to ground or VCC circuit
open
TP sensor, lead wire/coupler
connection
TP sensor circuit shorted to
VCC or ground circuit open
TP sensor circuit open or
shorted to ground or VCC circuit
open
ECT sensor, lead wire/coupler
connection
ECT sensor circuit open or
ground circuit open
ECT sensor circuit shorted to
ground
IAT sensor, lead wire/coupler
connection
IAT sensor circuit open or
ground circuit open
IAT sensor circuit shorted to
ground

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vzr1800

Table of Contents