Basic operator panel (BOP)
6.5 Auxiliary functions
After you have updated the firmware, you need to set parameters to their default values.
Refer to "Setting parameters to default (Page 155)" about the default process.
Note
Before you update the firmware, you can back up the drive data on a micro SD card/SD
card. If you want to use them after the update, you can copy the data from the micro SD
card/SD card to the drive (Page 157).
Improper firmware files will cause update failure.
When the update fails, the RDY indicator flashes red at 2 Hz and the COM indicator
becomes red on. An update failure is probably caused by improper firmware files or files
missing.
• If the firmware files on the micro SD card/SD card are corrupt, the servo drive cannot
• If the firmware on the micro SD card/SD card is the same with the current firmware of
When a failure occurs, try to update the firmware again using proper firmware files. If the
failure persists, contact your local distributor.
Note
Update the firmware by restarting the drive.
After inserting the micro SD card/SD card with proper firmware files, you can also update the
firmware by restarting the drive.
6.5.7

Adjusting AI offsets

NOTICE
Connect to ground
You must firstly connect the AI1 or AI2 to ground and then adjust AI offset.
Refer to section "Analog inputs (Page 101)".
158
CAUTION
start up after power-on.
the servo drive, only a restart is performed.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2015, A5E36037884