Technical Data - Servo Motors - Siemens SINAMICS V90 Operating Instructions Manual

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

General information
2.7 Technical data
2.7.2

Technical data - servo motors

General technical data
Parameter
Type of motor
Cooling
Relative humidity [RH]
Installation altitude [m]
Thermal class
Vibration severity grade
Shock resistance [m/s
]
2
Bearing lifetime [h]
Paint finish
Protection degree of shaft
Type of construction
Positive rotation
Certification
This lifetime is only for reference. When a motor keeps running at rated speed under rated load, replace its bearing after
1)
20,000 to 30,000 hours of service time. Even if the time is not reached, the bearing must be replaced when unusual
noise, vibration, or faults are found.
Specific technical data
SIMOTICS S-1FL6, low inertia servo motor
Order No.
1FL60...
Rated power [kW]
Rated torque [Nm]
Maximum torque [Nm]
Rated speed [rpm]
Maximum speed [rpm]
Rated frequency [Hz]
Rated current [A]
Maximum current [A]
Moment of inertia [10
-4
kgm
]
2
58
Description
Permanent-magnet synchronous motor
Self-cooled
90% (non-condensing at 30°C )
≤ 1000 (without power derating)
B
A (according to IEC 60034-14)
25 (continuous in axial direction); 50 (continuous in radial direction); 250
(in a short time of 6 ms)
> 20000
Black
IP 65, with shaft oil seal
IM B5, IM V1, and IM V3
Clockwise (default setting in SINAMICS V90 servo drives)
22
24
32
0.05
0.1
0.2
0.16
0.32
0.64
0.48
0.96
1.91
3000
5000
200
1.2
1.2
1.4
3.6
3.6
4.2
0.031
0.052
0.214
1)
34
42
0.4
0.75
1.27
2.39
3.82
7.2
2.6
4.7
7.8
14.2
0.351
0.897
Operating Instructions, 09/2015, A5E36037884
44
52
54
1
1.5
2
3.18
4.78
6.37
9.54
14.3
19.1
6.3
10.6
11.6
18.9
31.8
34.8
1.15
2.04
2.62
SINAMICS V90, SIMOTICS S-1FL6