Parameters
10.2 Parameter list
Par. No.
Name
p1007
Fixed speed setpoint 7
Description: Sets a value for the fixed speed / velocity setpoint 7.
p1058
Jog 1 speed setpoint
Description: Sets the speed/velocity for jog 1. Jogging is level-triggered and allows the motor to be incremen-
tally moved.
Note: The parameter values displayed on the BOP are integers.
p1082 *
Maximum speed
Description: Sets the highest possible speed.
Notice: After the value has been modified, no further parameter modifications can be made.
Note: The parameter values displayed on the BOP are integers.
The parameter applies for both motor directions.
The parameter has a limiting effect and is the reference quantity for all ramp-up and ramp-down times (e.g.
down ramps, ramp-function generator and motor potentiometer).
The range of the parameter is different when connect with different motors.
p1083 *
Speed limit in positive
direction of rotation
Description: Sets the maximum speed for the positive direction.
Note: The parameter values displayed on the BOP are integers.
p1086 *
Speed limit in negative
direction of rotation
Description: Sets the speed limit for the negative direction.
Note: The parameter values displayed on the BOP are integers.
p1115
Ramp-function generator
selection
Description: Sets the ramp-function generator type.
Note: Another ramp-function generator type can only be selected when the motor is at a standstill.
p1120
Ramp-function generator
ramp-up time
Description: The ramp-function generator ramps-up the speed setpoint from standstill (setpoint = 0) up to the
maximum speed (p1082) in this time.
Dependency: Refer to p1082
p1121
Ramp-function generator
ramp-down time
Description: Sets the ramp-down time for the ramp-function generator.
The ramp-function generator ramps-down the speed setpoint from the maximum speed (p1082) down to
standstill (setpoint = 0) in this time.
Further, the ramp-down time is always effective for OFF1.
Dependency: Refer to p1082
p1130
Ramp-function generator
initial rounding-off time
Description: Sets the initial rounding-off time for the extended ramp generator. The value applies to ramp-up
and ramp-down.
Note: Rounding-off times avoid an abrupt response and prevent damage to the mechanical system.
278
Min
Max
-210000.000
210000.000 0.000
0.00
210000.000 100.00
0.000
210000.000 1500.00
0.000
210000.000 210000.
-210000.000
0.000
0
1
0.000
999999.000 1
0.000
999999.000 1
0.000
30.000
Factory
Unit
Data
Setting
type
rpm
Float
rpm
Float
rpm
Float
0
rpm
Float
000
-
rpm
Float
210000.
000
0
-
I16
s
Float
s
Float
0.000
s
Float
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2015, A5E36037884
Effective
Can be
changed
IM
T, U
IM
T
IM
T
IM
T, U
IM
T, U
IM
T
IM
T, U
IM
T, U
IM
T, U