Par. No.
Name
p29350
Select sources for analog
output 1
Description: Selects signal source for analog output 1.
0: Actual speed (reference p29060)
1: Actual torque (reference 3 × r0333)
2: Speed setpoint (reference p29060)
3: Torque setpoint (reference 3 × r0333)
4: DC bus voltage (reference 1000 V)
5: Pulse input frequency (reference 1k)
6: Pulse input frequency (reference 10k)
7: Pulse input frequency (reference 100k)
8: Pulse input frequency (reference 1000k)
9: Remaining number of pulses (reference 1k)
10: Remaining number of pulses (reference 10k)
11: Remaining number of pulses (reference 100k)
12: Remaining number of pulses (reference 1000k)
p29351
Select Signal Source for
Analog 2
Description: Selects signals for analog output 2.
0: Actual speed (reference p29060)
1: Actual torque (reference 3 × r0333)
2: Speed setpoint (reference p29060)
3: Torque setpoint (reference 3 × r0333)
4: DC bus voltage (reference 1000 V)
5: Pulse input frequency (reference 1k)
6: Pulse input frequency (reference 10k)
7: Pulse input frequency (reference 100k)
8: Pulse input frequency (reference 1000k)
9: Remaining number of pulses (reference 1k)
10: Remaining number of pulses (reference 10k)
11: Remaining number of pulses (reference 100k)
12: Remaining number of pulses (reference 1000k)
p31581
VIBSUP: Filter type
Description: Sets the filter type for VIBSUP. Depending on the selected filter type, the VIBSUP filter results in
motion sequences that take somewhat longer.
0: The rugged VIBSUP filter has a lower sensitivity to frequency offsets compared with the sensitive filter
type, but results in a higher delay of the motion sequence. The total motion sequence is extended by the
time period T
1: The sensitive VIBSUP filter has a higher sensitivity to frequency offsets compared with the rugged filter
type, but results in a lower delay of the motion sequence. The total motion sequence is extended by half
the time period T
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2015, A5E36037884
Min
0
0
0
(T
= 1/f
).
d
d
d
/2 (T
= 1/f
).
d
d
d
Max
Factory
Unit
Setting
12
0
-
12
1
-
1
0
-
Parameters
10.2 Parameter list
Data
Effective
type
U16
IM
U16
IM
I16
IM
Can be
changed
T
T
T
305