Technical Data; Technical Data - Servo Drives - Siemens SINAMICS V90 Operating Instructions Manual

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

General information

2.7 Technical data

2.7
Technical data
2.7.1

Technical data - servo drives

General technical data
Parameter
24 VDC
Voltage (V)
power
Maximum current (A)
supply
Overload capability
Control system
Dynamic brake
Protective functions
Speed
Speed control range
control
Analog speed command
mode
input
Torque limit
Position
Max. input pulse frequency
control
Command pulse multiplying
mode
factor
In-position range setting
Error excessive
Torque limit
Torque
Analog torque command
control
input
mode
Speed limit
54
Description
24 (-15% to +20%)
1)
1.6 A (when using a motor without a brake)
3.6 A (when using a motor with a brake)
300%
Servo control
Built-in
Earthing fault protection, output short-circuit protection
age/undervoltage protection, I
tion
3)
Analog speed command 1:2000, internal speed command 1:5000
-10 VDC to +10 VDC/rated speed
Set through a parameter or the analog input command (0 VDC to +10 VDC/max.
torque)
1 M (differential input), 200 kpps (open collector input)
Electronic gear ratio (A/B)
A: 1 - 10000, B: 1 - 10000
1/50 <A/B < 200
0 to ±10000 pulse (command pulse unit)
±1/10 revolutions
Set through a parameter or the analog input command (0 VDC to +10 VDC/max.
torque)
-10 VDC to +10VDC/max. torque (input impedance 10 kΩ to 12 kΩ)
Set through a parameter or the analog input command (0 VDC to +10 VDC/max.
rated speed)
2)
t inverter,I
t motor, IGBT overtemperature protec-
2
2
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2015, A5E36037884
, overvolt-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fl6

Table of Contents