Diagnostics
11.2 List of faults and alarms
Fault
F7490: Enable signal with-
drawn while traversing
Reaction: OFF1
Acknowledgement:
IMMEDIATELY
F7491: STOP cam minus
reached
Reaction: OFF3
Acknowledgement:
IMMEDIATELY
F7492: STOP cam plus
reached
Reaction: OFF3
Acknowledgement:
IMMEDIATELY
F7493: LR: Overflow of the
value range for position actu-
al value
Reaction: OFF1 (OFF2,
OFF3)
Acknowledgement:
IMMEDIATELY
F7599: Encoder 1: Adjust-
ment not possible
Reaction: OFF1 (NONE,
OFF2, OFF3)
Acknowledgement:
IMMEDIATELY
F7800 Drive: No power unit
present
Reaction: NONE
Acknowledgement:
IMMEDIATELY
324
Cause
For a standard assignment, another
fault may have occurred as a result of
withdrawing the enable signals.
The drive is in the "switching on inhibit-
ed" state (for a standard assignment).
The STOP cam minus was reached. For a
positive traversing direction, the STOP
cam minus was reached, i.e. the wiring of
the STOP cam is incorrect.
The STOP cam plus was reached. For a
negative traversing direction, the STOP
cam plus was reached, i.e. the wiring of
the STOP cam is incorrect.
The value range (-2147483648 ...
2147483647) for the position actual value
representation was exceeded. When the
overflow occurs, the "referenced" or "ad-
justment absolute measuring system"
status is reset.
The position actual value (r2521) has
exceeded the value range.
The encoder position actual value has
exceeded the value range.
The maximum encoder value times the
factor to convert the absolute position
from increments to length units (LU)
has exceeded the value range for dis-
playing the position actual value.
The maximum encoder value times the
factor to convert the absolute position from
increments to length units (LU) has ex-
ceeded the value range (-2147483648 ...
2147483647) for displaying the position
actual value.
The power unit parameters cannot be read
or no parameters are stored in the power
unit.
Remedy
Set the enable signals or check the cause
of the fault that first occurred and then re-
sult (for a standard assignment).
Check the assignment to enable the basic
positioning function.
Leave the STOP cam minus in the posi-
tive traversing direction and return the ax-
is to the valid traversing range.
Check the wiring of the STOP cam.
Leave the STOP cam plus in the negative
traversing direction and return the axis to
the valid traversing range.
Check the wiring of the STOP cam.
If required, reduce the traversing range or
position resolution p29247.
Note for case = 3:
If the value for the maximum possible abso-
lute position (LU) is greater than 4294967296,
then it is not possible to
make an adjustment due to an overflow.
For rotary encoders, the maximum possible
absolute position (LU) is calculated as fol-
lows:
Motor encoder without position tracking:
IPos: p29247 * p29248 * 4096 / p29249
for multiturn encoders
PTI: 1048576 * p29012[X] * 4096
/ p29013 for multiturn encoders
If the value for the maximum possible abso-
lute position (LU) is greater than 4294967296,
then it is not possible to make an adjustment
due to an overflow.
For rotary encoders, the maximum possible
absolute position (LU) is calculated as fol-
lows:
Motor encoder without position tracking:
IPos: p29247 * p29248 * 4096 / p29249
for multiturn encoders
PTI: 1048576 * p29012[X] * 4096
/ p29013 for multiturn encoders
Carry out a POWER ON (power off/on) for
all components.
Change the module.
SINAMICS V90, SIMOTICS S-1FL6