Motor Power - U, V, W - Siemens SINAMICS V90 Operating Instructions Manual

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

SINAMICS V90 400 V variant
Maximum conductor cross-section:
FSAA and FSA: 1.5 mm
FSB and FSC: 2.5 mm
Note
For 200 V variant, when using the FSA, FSB and FSC on the single phase power network,
you can connect the power supply to any two connectors of L1, L2, and L3.
4.2.2

Motor power - U, V, W

Motor output - drive side
SINAMICS V90 200 V variant
Required wire range and tightening torque:
FSA and FSB: 26 AWG to 12 AWG
FSC and FSD: 20 AWG to 12 AWG, 0.4 Nm to 0.5 Nm
SINAMICS V90 400 V variant
Maximum conductor cross-section:
FSAA and FSA: 1.5 mm
FSB and FSC: 2.5 mm
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2015, A5E36037884
Signal
L1
L2
L3
(M2.5 screws, 4.43 lb.in/0.5 Nm)
2
(M4 screws, 19.91 lb.in/2.25 Nm)
2
Signal
U
V
W
Signal
U
V
W
(M2.5 screws, 4.43 lb.in/0.5 Nm)
2
(M4 screws, 19.91 lb.in/2.25 Nm)
2
4.2 Main circuit wirings
Description
Line phase L1
Line phase L2
Line phase L3
Description
Motor phase U
Motor phase V
Motor phase W
Description
Motor phase U
Motor phase V
Motor phase W
Connecting