Connecting
4.3 Control/Status interface
No.
Name
Type
13
CCWE
Level
14
ZSCLAMP
Level
15
SPD1
Level
16
SPD2
Level
17
SPD3
Level
18
TSET
Level
19
SLIM1
Level
20
SLIM2
Level
94
Description
Enable counter-clockwise rotations.
1: Enable counter-clockwise rotation, ramp down
0: Disable counter-clockwise rotation, ramp up
Zero speed clamps.
1 = when the motor speed setpoint is an analog
signal and lower than the threshold level (p29075),
the motor is clamped.
0 = no action
Select speed mode: fixed speed setpoint.
A combination of the signals SPD1, SPD2 and SPD3
can select eight speed setpoint sources (one external
speed setpoint, seven fixed speed setpoints).
SPD3 : SPD2 : SPD1
0 : 0 : 0: external analog speed setpoint
0 : 0 : 1: fixed speed setpoint 1
0 : 1 : 0: fixed speed setpoint 2
0 : 1 : 1: fixed speed setpoint 3
1 : 0 : 0: fixed speed setpoint 4
1 : 0 : 1: fixed speed setpoint 5
1 : 1 : 0: fixed speed setpoint 6
1 : 1 : 1: fixed speed setpoint 7
Torque setpoint selection.
This signal can select two torque setpoint sources
(one external torque setpoint, one fixed torque set-
point).
0: external torque setpoint (analog input 2)
1: fixed torque setpoint
Speed limit selection.
A combination of SLIM1 to SLIM2 can select four
speed limit sources (one external speed limit, three
internal speed limits).
SLIM2 : SLIM1
0 : 0: internal speed limit 1
0 : 1: external speed limit (analog input 1)
1 : 0: internal speed limit 2
1 : 1: internal speed limit 2
Control mode
PTI
IPos
X
X
X
X
X
X
X
X
SINAMICS V90, SIMOTICS S-1FL6