10.2 Parameter list
Par. No.
Name
p29010
PTI: Selection of input
pulse form
Description: Selection of setpoint pulse train input form. After changing of p29010, reference point will lost,
A7461 will remind user to referencing again.
0: Pulse + direction, positive logic
1: AB phase, positive logic
2: Pulse + direction, negative logic
3: AB phase, negative logic
p29011
PTI: Number of Setpoint
Pulse Per Revolution
Description: The number of setpoint pulses per motor revolution. The servo motor rotates for one revolution
when the number of the setpoint pulses reaches this value.
When this value is 0, the number of required setpoint pulses is decided by the electronic gear ratio.
p29012[0..
PTI: Numerator of Elec-
.3]
tronic Gear
Description: The numerator of the electronic gear ratio for the setpoint pulses. For the servo system with an
absolute encoder, the value range of p29012 is 1 to 10000.
Four numerators in total are available. You can select one of the numerators by configuring the digital input
signal EGEAR.
For detailed information about the calculation of a numerator, refer to the SINAMICS V90 Operating Instruc-
tions or use SINAMICS V-ASSISTANT to do the calculation.
p29013
PTI: Denominator of
Electronic Gear
Description: The denominator of the electronic gear for the setpoint pulses.
p29014
PTI: Selection of Pulse
input Electrical Level
Description: Selection of a logic level for the setpoint pulses.
0: 5 V
1: 24 V
p29016
PTI: Pulse Input Filter
Description: Select filter for PTI input to get better EMC performance, 0 for low frequency PTI input, 1 for high
frequency PTI input.
p29019
RS485 monitor time
Description: Sets the monitoring time to monitor the process data received via the RS485 bus interface. If no
process data is received within this time, then an appropriate message is output.
Note: If p29019 = 0, monitoring is deactivated.
p29020[0..
Tuning: Dynamic factor
.1]
Description: The dynamic factor of auto tuning. 35 dynamic factors in total are available.
Index:
[0]: Dynamic factor for one-button auto tuning
[1]: Dynamic factor for real-time auto tuning
292
Min
Max
0
3
0
16777215
1
10000
1
10000
0
1
0
1
0
1999999
1
35
Factory
Unit
Data
Setting
type
0
-
U16
0
-
U32
1
-
U32
1
-
U32
1
-
I16
[0] 0
-
I16
0
ms
Float
18
-
U16
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2015, A5E36037884
Effective
Can be
changed
RE
T
IM
T
IM
T
IM
T
IM
T
IM
T
IM
T
IM
T, U