Parameters
10.2 Parameter list
Par. No.
Name
p29333
Digital Output 4 Assign-
ment
Description: Defines the function of digital output signal DO4
p29334
Digital Output 5 Assign-
ment
Description: Defines the function of digital output signal DO5
p29335
Digital Output 6 Assign-
ment
Description: Defines the function of digital output signal DO6
p29340
Warning 1 Assigned for
Digital Output
Description: Defines conditions for WRN1.
1: Motor overload protection warning: 85% of overload threshold has been reached.
•
2: Holding brake power overload warning: 85% of overload threshold has been reached.
•
3: Fan warning: fan has stopped for more than 1 s.
•
4: Encoder warning
•
5: Motor overtemperature warning: 85% of overtemperature threshold has been reached.
•
6: Capacitor service life warning: The capacitor has reached its expiry, so replace it.
•
p29341
Warning 2 Assigned for
Digital Output
Description: Defines conditions for WARNING2.
1: Motor overload protection warning: 85% of overload threshold has been reached.
•
2: Holding brake power overload warning: 85% of overload threshold has been reached.
•
3: Fan warning: life time of fan expired (40000 hours), replacement of fan needed.
•
4: Encoder warning
•
5: Motor overtemperature warning: 85% of overtemperature threshold has been reached.
•
6: Capacitor service life warning: The capacitor has reached its expiry, so replace it.
•
304
Min
Max
1
14
1
14
1
14
1
6
1
6
Factory
Unit
Data
Setting
type
5
-
I16
6
-
I16
8
-
I16
1
-
U16
2
-
U16
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2015, A5E36037884
Effective
Can be
changed
IM
T
IM
T
IM
T
IM
T
IM
T