Siemens SINAMICS V90 Operating Instructions Manual page 290

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

Parameters
10.2 Parameter list
Par. No.
Name
p2691
MDI speed fixed setpoint
Description: Sets a fixed setpoint for the speed.
p2692
MDI acceleration over-
ride, fixed setpoint
Description: Sets a fixed setpoint for the acceleration override.
Note: The percentage value refers to the maximum acceleration (p2572).
p2693
MDI deceleration over-
ride, fixed setpoint
Description: Sets a fixed setpoint for the deceleration override.
Note: The percentage value refers to the maximum deceleration (p2573).
p29000 *
Motor ID
Description: Motor type number is printed on the motor rating plate as motor ID.
For a motor with an incremental encoder, users need to manually input the parameter value. The range of
high inertia motor is 18 to 39; the range of low inertia motor is 42 to 71.
For a motor with an absolute encoder, the drive automatically reads the parameter value. The range of high
inertia motor with multi-turn encoder is 10009 to 10048.
p29001
Reversal of motor direc-
tion
Description: Reversal of motor running direction. By default, CW is the positive direction while CCW the nega-
tive direction. After changing of p29001, reference point will lost, A7461 will remind user to referencing again.
0: No reversal
1: Reverse
p29002
BOP display selection
Description: Selection of BOP operating display.
0: Actual speed (default)
1: DC voltage
2: Actual torque
3: Actual position
4: Position following error
p29003
Control mode
Description: Selection of control mode.
0: Position control with pulse train input (PTI)
1: Internal position control (IPos)
2: Speed control (S)
3: Torque control (T)
4: Control change mode: PTI/S
5: Control change mode: IPos/S
6: Control change mode: PTI/T
7: Control change mode: IPos/T
8: Control change mode: S/T
290
Min
Max
1
40000000
0.100
100.000
0.100
100.000
0
65535
0
1
0
4
0
8
Factory
Unit
Data
Setting
type
600
100
U32
0
LU/
min
100.000 %
Float
100.000 %
Float
0
-
U16
0
-
I16
0
-
I16
0
-
U16
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2015, A5E36037884
Effective
Can be
changed
IM
T, U
IM
T, U
IM
T, U
IM
T
IM
T
IM
T, U
RE
T

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fl6

Table of Contents