No.
Name
Type
3
CWL
Edge
1→0
4
CCWL
Edge
1→0
5
G-
Level
CHANGE
6
P-TRG
Level
(P_TRG in
Edge
PTI mode is
0→1
reserved for
future use)
7
CLR
Level
8
EGEAR1
Level
9
EGEAR2
Level
10
TLIM1
Level
11
TLIM2
Level
12
CWE
Level
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2015, A5E36037884
Description
Clockwise over-travel limit (positive limit)
1 = condition for operation
•
1→0: emergency stop (OFF3)
•
Counter-clockwise over-travel limit (negative limit)
1 = condition for operation
•
1→0: emergency stop (OFF3)
•
Gain change between the first and the second gain
parameter set.
0: the first gain parameter set
•
1: the second gain parameter set
•
In PTI mode: pulse allowable/inhibit.
0: operation with pulse train setpoint is possible
•
1: inhibit the pulse train setpoint
•
In IPos mode: position trigger
0→1: starts positioning of selected fixed position
•
setpoint
Clear position control droop pulses.
0: not clear
•
1: clear the droop pulses based on the selected
•
clear mode by p29242
Electronic gear.
A combination of the signals EGEAR1 and EGEAR2
can select four electronic gear ratios.
EGEAR2 : EGEAR1
0 : 0: electronic gear ratios 1
•
0 : 1: electronic gear ratios 2
•
1 : 0: electronic gear ratios 3
•
1 : 1: electronic gear ratios 4
•
Torque limit selection.
A combination of TLIM1 and TLIM2 can select four
torque limit sources (one external torque limit, three
internal torque limits).
TLIM2 : TLIM1
0 : 0: internal torque limit 1
•
0 : 1: external torque limit (analog input 2)
•
1 : 0: internal torque limit 2
•
1 : 1: internal torque limit 3
•
Enable clockwise rotations.
1: Enable clockwise rotation, ramp up
•
0: Disable clockwise rotation, ramp down
•
Connecting
4.3 Control/Status interface
Control mode
PTI
IPos
S
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
X
✓
X
X
✓
X
X
✓
X
X
✓
✓
✓
X
X
✓
T
✓
✓
X
X
X
X
X
X
✓
93