Par. No.
Name
p29307[0..
Digital Input 7 Assign-
.3]
ment
Description: Defines the function of digital input signal DI7
Index:
[0]: DI7 for Control mode 0
•
[1]: DI7 for Control mode 1
•
[2]: DI7 for Control mode 2
•
[3]: DI7 for Control mode 3
•
p29308[0..
Digital Input 8 Assign-
.3]
ment
Description: Defines the function of digital input signal DI8
Index:
[0]: DI8 for Control mode 0
•
[1]: DI8 for Control mode 1
•
[2]: DI8 for Control mode 2
•
[3]: DI8 for Control mode 3
•
p29330
Digital Output 1 Assign-
ment
Description: Defines the function of digital output signal DO1
1: RDY
•
2: FAULT
•
3: INP
•
4: ZSP
•
5: SPDR
•
6: TLR
•
7: SPLR
•
8: MBR
•
9: OLL
•
10: WARNING1
•
11: WARNING2
•
12: REFOK
•
13: CM_STA
•
14: RDY_ON
•
p29331
Digital Output 2 Assign-
ment
Description: Defines the function of digital output signal DO2
p29332
Digital Output 3 Assign-
ment
Description: Defines the function of digital output signal DO3
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2015, A5E36037884
Min
Max
0
28
0
28
1
14
1
14
1
14
Factory
Unit
Data
Setting
type
[0] 7; [1]
-
I16
21; [2]
15; [3]
18
[0] 10;
-
I16
[1] 22;
[2] 16;
[3] 19
1
-
I16
2
-
I16
3
-
I16
Parameters
10.2 Parameter list
Effective
Can be
changed
IM
T
IM
T
IM
T
IM
T
IM
T
303