Show Module Alarms; Show Module Ansistats - Avaya 2330 Reference Manual

Advanced gateway
Hide thumbs Also See for 2330:
Table of Contents

Advertisement

show module alarms

Use this command to display the alarms detected on an E1 or T1 module.
This command also shows individual user threshold alarms for all user statistics currently
configured with alarm thresholds. To view the current user alarm threshold settings, use the
show module thresholds command.
To display the alarms in real-time, specify the desired refresh interval in minutes when entering
this command. To return to the system command prompt, type q.
Syntax
show module alarms {e1|t1} <slot/port> [refresh_interval <1-65535>]
Table 57: Variable definitions
Variable
[refresh_interval <1-65535>] Specifies how often, in minutes, the alarm display is updated
Example
AG# show module alarms t1 2/1

show module ansistats

Use this command to display ANSI statistics for a T1 interface.
The command shows the current 15-minute interval statistics, the elapsed time in the current
sampling interval, and the total counts for the past 8 hours. These statistics can be cleared
only by the carrier by FDL requests from the remote end.
You can view statistics for multiple 15-minute intervals by specifying the number of intervals
you wish to view (from 1 to 96).
Syntax
show module ansistats t1 <slot/port> [interval_range <1-96>]
Example
AG# show module ansistats t1 2/1
Command Line Reference
(optional entry; minimum is 1 minute). If you do not specify
an interval, you must repeat the command to update the
alarm display.
show module alarms
Value