T1/E1 module configuration commands
rising-threshold
sampling-interval
Example
AG/configure/module/e1 (3/1)/alarms/thresholds# user 1 ses 300 50 30
In this example, the monitored parameter is the number of Severely Errored Seconds that
occur. The sampling interval is set to 300 seconds (5 minutes). The rising alarm threshold is
50 SES and the falling alarm threshold is 30 SES. Delta sampling is used (by default), in which
a rising alarm is reported if the SES count increases by 20 (50 - 30 = 20) during any sampling
interval. Similarly, a falling alarm is reported if the SES count decreases by 20 during any
interval.

configure module e1 alarms hierarchy

Use this command to enable or disable the hierarchy for displaying Receive Loss of Signal
(RLOS) and Receive Loss of Frame (RLOF) on an E1 link.
Syntax
[no] alarms hierarchy
Table 32: Variable definitions
no
Example
AG/configure/module/e1 (3/1)# alarms hierarchy

configure module e1 circuitId

Use this command to specify an optional circuit ID for the E1 interface.
Syntax
cicuitId <circuit-id>
64
Command Line Reference
Variable
Comments? infodev@avaya.com
Number of errored seconds or events which,
if exceeded during any sampling interval,
results in a rising alarm. The range is 0 -
2147483647
Sampling interval, in seconds. The range is
1 - 65535.
Value
Disables hierarchy.