Configure Module T1 Alarms Thresholds User - Avaya 2330 Reference Manual

Advanced gateway
Hide thumbs Also See for 2330:
Table of Contents

Advertisement

Syntax
yellow_alarm {generate | detect | gen_det | disable}
Table 42: Variable definitions
Variable
detect
disable
gen_det
generate
Example
AG/configure/module/e1 (3/1)/alarms/thresholds# yellow_alarm gen_det

configure module t1 alarms thresholds user

Use this command to set the T1 user statistic alarm thresholds.
When user-configurable thresholds are exceeded, the AG2330 generates alarms that indicate
the possible deterioration of a T1 link. Refer to the following parameters to determine the
specific T1 data type that needs to be configured. You can define one alarm threshold for each
parameter.
Syntax
alarms thresholds user < 1 - 10 > [ ses | es | uas | eev | css | oof
| crc | bpv ] < sampling-interval > < rising-threshold > < falling-
threshold > sample_type [ absolute | delta ]
Table 43: Variable definitions
1-10
absolute | delta
Command Line Reference
Variable
configure module t1 alarms thresholds user
Value
Detect incoming yellow alarms from the
network.
Disable yellow alarm generator.
Generate and detect yellow alarms (default
state).
Generate and send yellow alarms to the
network.
Value
Alarm threshold number.
absolute: The errored second or event count
is compared directly to the specified
threshold values, and the appropriate alarm
type (rising or falling) is reported. delta: The
errored second or event count is compared
to the difference between the rising and
falling thresholds, and a rising alarm is
reported if the actual error count exceeds
August 2013
69