5.5 E: Motor Parameters
n
V/f Pattern Settings E1-04 to E1-10
Set up the V/f pattern as shown in
No.
E1-04
E1-05
E1-06
E1-07
E1-08
E1-09
E1-10
<1> Values shown here are for 200 V class drives; double the values for 400 V class drives.
Note:
1. The following condition must be true when setting up the V/f pattern: E1-09 ≤ E1-07 ≤ E1-06 ≤ E1-04
2. To make the V/f pattern a straight line set E1-09 = E1-07. In this case the E1-08 setting is disregarded.
3. E1-03 is unaffected when the drive is initialized using parameter A1-03, but the settings for E1-04 through E1-10 are returned to their
default values.
u

E2: Motor 1 Parameters

These parameters contain the most important motor data needed for optimal motor control.
n
E2-01: Motor Rated Current
Set E2-01 to the full load amps (FLA) stamped on the motor nameplate.
No.
E2-01
Note:
Change E2-01 after changing the value set to E2-03. Setting E2-01 < E2-03 will trigger an oPE02 error.
n
E2-02: Motor Rated Slip
Sets the motor rated slip in Hz.
No.
E2-02
Calculate the motor rated slip using the information written on the motor nameplate and the formula below:
E2-02 = f - (n x p)/120
(f: rated frequency (Hz), n: rated motor speed (r/min), p: number of motor poles)
n
E2-03: Motor No-Load Current
Set E2-03 to the motor no-load current at rated voltage and rated frequency. Contact the motor manufacturer for information
about the no-load current.
96
Figure
5.13.
Parameter Name
Maximum Output Frequency
Maximum Voltage
Base Frequency
Middle Output Frequency
Middle Output Frequency Voltage
Minimum Output Frequency
Minimum Output Frequency Voltage
Output Voltage (V)
E1-05
E1-08
E1-10
E1-09
Figure 5.13 V/f Pattern
Parameter Name
Motor Rated Current
Parameter Name
Motor Rated Slip
YASKAWA ELECTRIC SIEP C710606 31B YASKAWA AC Drive – J1000 Technical Manual
http://nicontrols.com
Setting Range
40.0 to 400.0 Hz
0.0 to 255.0 V
0.0 to 400.0 Hz
0.0 to 400.0 Hz
0.0 to 255.0 V
0.0 to 400.0 Hz
0.0 to 255.0 V
E1-07 E1-06
E1-04
Frequency (Hz)
Setting Range
10% to 200% of the drive
rated current.
(unit: 0.01 A)
Setting Range
0.00 to 20.00 Hz
Default
60 Hz
<1>
230 V
60 Hz
3.0 Hz
<1>
18.4 V
1.5 Hz
<1>
13.8 V
Default
Depending on
o2-04
Default
Depending on
o2-04