Page 1
YASKAWA AC Drive-J1000 Option Potentiometer Technical Manual Type AI-V3/J To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance. Ensure the end user receives this manual. オプションユニッ ト J1000 周波数設定ボリューム ユニッ ト 取扱説明書...
1 Preface and Safety ◆ Applicable Documentation The following manuals are available for the Potentiometer Option: Option Unit Yaskawa AC Drive - J1000 Option Potentiometer Technical Manual J1000 Read this manual first. The Technical Manual is packaged with the Potentiometer Option and contains a basic overview of wiring, settings, functions, and fault diagnoses.
Page 6
Yaskawa sales office or the nearest Yaskawa representative. ◆ Terms Note: Indicates a supplement or precaution that does not cause drive damage. Drive: Yaskawa AC Drive -J1000 Series Option: Yaskawa AC Drive -J1000 Potentiometer Option YASKAWA ELECTRIC TOBPC73060034A Potentiometer Technical Manual...
Page 7
DANGER Indicates a hazardous situation, which, if not avoided, will result in death or serious injury. W ARNING Indicates a hazardous situation, which, if not avoided, could result in death or serious injury. YASKAWA ELECTRIC TOBPC73060034A Potentiometer Technical Manual...
Page 8
1 Preface and Safety CAUTION Indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury. NOTICE Indicates an equipment damage message. YASKAWA ELECTRIC TOBPC73060034A Potentiometer Technical Manual...
• Technical Manual ◆ Tool Requirements Use a flat-blade screwdriver with the dimensions below for installation or removal of the option cover and Potentiometer Option. Blade width 3.0 mm max. Blade thickness 0.6 mm max. YASKAWA ELECTRIC TOBPC73060034A Potentiometer Technical Manual...
Turning the potentiometer changes the frequency reference making it easier to adjust the motor speed. ◆ Applicable Models Potentiometer Option can be used with these Yaskawa drive models. Drive Drive Software Version <1> ≥1010 CIMR-J <1>...
Dial Connector B – Option Model D – Connection Number Tabs ◆ Dimensions The installed option adds 21 mm (0.83 in) to the total depth of the drive. 6 (0.24) mm (in) 15 (0.60) YASKAWA ELECTRIC TOBPC73060034A Potentiometer Technical Manual...
DC bus voltage is below 50Vdc. Measure drive DC bus voltage to confirm safe level. NOTICE Damage to Equipment Properly connect the connectors. Failure to comply may prevent proper operation and possibly damage equipment. YASKAWA ELECTRIC TOBPC73060034A Potentiometer Technical Manual...
Page 13
CN5 port on the drive, and click it into place. NOTICE: Damage to equipment. Make necessary parameter adjustments after installing the Potentiometer Option. Failing to follow these installation instructions may damage the drive. Flat-blade screwdriver CN5 port Connection tabs YASKAWA ELECTRIC TOBPC73060034A Potentiometer Technical Manual...
Page 14
Insert a flat-blade screwdriver into the small opening between the drive and the option. Gently apply pressure to the connection tabs to disconnect the option as shown. J 1 0 Underside of option Flat-blade screwdriver YASKAWA ELECTRIC TOBPC73060034A Potentiometer Technical Manual...
2. Adjust the frequency reference by turning the potentiometer dial. NOTICE: Damage to equipment. Use caution when setting the frequency reference by adjusting the potentiometer dial slowly. Sudden changes to the frequency reference can damage the drive and connected machinery. YASKAWA ELECTRIC TOBPC73060034A Potentiometer Technical Manual...
Selection 1 terminal A1. 2 : MEMOBUS/Modbus communications 3 : Option PCB Analog Input Sets the primary delay filter H3-13 Filter Time time constant for terminal A1. 0.03 s Constant Used for noise filtering. YASKAWA ELECTRIC TOBPC73060034A Potentiometer Technical Manual...
8 Troubleshooting 8 Troubleshooting Problems with the option interface may trigger an operator error. Refer to the J1000 Technical Manual for errors not listed in this manual. ◆ Fault LED Operator Fault Name Display oFA01 Option Unit Fault Cause Possible solution...
Indoors (an area free from oil mist and dust) Area Ambient -10 to +50°C Temperature Humidity 95% RH or less with no condensation Storage -20 to +60°C allowed for short-term transport of Temperature the product Altitude 1000 m or less YASKAWA ELECTRIC TOBPC73060034A Potentiometer Technical Manual...
Published in Japan July 2008 08-2 Revision number Date of publication Date of original publication Date of Rev. Section Revised Content Publication February 2008 – – First edition July 2008 Chapter 10 Revision: Address YASKAWA ELECTRIC TOBPC73060034A Potentiometer Technical Manual...