6.3 Drive Alarms, Faults, and Errors
LED Operator Display
Drive specification mismatch during
CPF06
Terminal Board or Control Board
replacement
EEPROM Serial Communications
CPF08
Fault
RAM Fault
FLASH Memory Fault
or
CPF20 or
<2>
CPF21
Watchdog Circuit Exception
Clock Fault
CPF22
A/D Conversion Error
CPF23
PWM Feedback Data Fault
CPF24
Drive Capacity Signal Fault
EF0
Option Unit External Fault
EF1 to
External Fault (input terminal S1 to
to
EF5
S5)
Err
EEPROM Write Error
<1> Displayed as
when occurring at drive power up. When one of the faults occurs after successfully starting the drive, the display will show
.
<2> Displayed as
when occurring at drive power up. When one of the faults occurs after successfully starting the drive, the display will show
.
<3> Uv1 fault is not saved to the fault history
n
Minor Faults and Alarms
When a minor fault or alarm occurs, the ALM LED flashes and the text display shows an alarm code. A fault has occurred if
the text remains lit and does not flash.
trigger both faults and minor faults. It is therefore important to note whether the LEDs remain lit or if the LEDs flash.
LED Operator Display
bb
CALL
CE
CrST
EF
to
EF1 to EF5 External Fault (input terminal S1 to S5)
oH
oL3
ov
PASS
SE
Uv
n
Operation Errors
LED Operator
Display
oPE01
Drive Unit Setting Error
oPE02
Parameter Setting Range Error
oPE03
Multi-Function Input Setting Error
132
Name
Pg.
133
134
134
134
134
134
134
134
134
134
134
135
Refer to Alarm Detection on page
Table 6.5 Minor Fault and Alarm Displays
Name
Drive Baseblock
Serial Communication Transmission Error
MEMOBUS/Modbus Communication Error
Cannot Reset
Run Command Input Error
Heatsink Overheat
Overtorque 1
Overvoltage
MEMOBUS/Modbus Test Mode Complete
MEMOBUS/Modbus Test Mode Fault
Undervoltage
Table 6.6 Operation Error Displays
Name
Pg.
144
144
144
YASKAWA ELECTRIC SIEP C710606 31B YASKAWA AC Drive – J1000 Technical Manual
http://nicontrols.com
LED Operator Display
LF
Output Phase Loss
oC
Overcurrent
oFA01
Option Disconnected
oH1
Heatsink Overheat
oL1
Motor Overload
oL2
Drive Overload
oL3
Overtorque Detection 1
oPr
Operator Connection Fault
ov
Overvoltage
PF
Input Phase Loss
rH
Dynamic Braking Resistor
<3>
Uv1
Undervoltage
Uv3
Soft Charge Circuit Fault
140. An overvoltage situation, for example, can
Minor Fault Output
LED Operator
Display
oPE05
Run Command Selection Error
oPE10
V/f Data Setting Error
oPE11
Carrier Frequency Setting Error
Name
Pg.
135
135
136
136
136
137
137
137
142
138
138
139
139
Pg.
(H2-01 = 10)
No output
140
YES
140
YES
140
YES
140
YES
141
YES
141
YES
141
YES
141
YES
142
No output
142
YES
142
YES
142