Fault History Contents

The table below shows the fault codes that can be read out by MEMOBUS/Modbus commands from the U2-oo monitor
parameters.
Note:
Uv1 fault is not saved to the fault history.
Fault Code
0002H
Undervoltage (Uv1)
0004H
Soft Charge Circuit Fault (Uv3)
0007H
Overcurrent (oC)
0008H
Overvoltage (ov)
000AH
Heatsink Overheat (oH1)
000BH
Motor Overload (oL1)
000CH
Drive Overload (oL2)
000DH
Overtorque Detection 1 (oL3)
0010H
Braking Resistor Overheat (rH)
0011H
External Fault at input terminal S3 (EF3)
0012H
External Fault at input terminal S4 (EF4)
0013H
External Fault at input terminal S5 (EF5)
001BH
Input Phase Loss (PF)
001CH
Output Phase Loss (LF)
001EH
Digital Operator Connection (oPr)
001FH
EEPROM Write Error (Err)
0021H
MEMOBUS/Modbus Communication Error (CE)
0027H
PROFIBUS-DP Option External Fault (EF0)
u

Alarm Register Contents

The table below shows the alarm codes that can be read out from MEMOBUS/Modbus register 007FH.
Alarm Code
0001H
Undervoltage (Uv)
0002H
Overvoltage (ov)
0003H
Heatsink Overheat (oH)
0005H
Overtorque 1 (oL3)
0007H
Run commands input error (EF)
0008H
Drive Baseblock (bb)
0009H
External Fault 3, input terminal S3 (EF3)
000AH
External Fault 4, input terminal S4 (EF4)
YASKAWA ELECTRIC SIEP C710606 31B YASKAWA AC Drive – J1000 Technical Manual
Table C.4 Fault History Register Contents
Fault Name
Table C.5 Alarm Register 007FH Contents
Fault Name
http://nicontrols.com
C.10 MEMOBUS/Modbus Data Table
Fault Code
0042H
External Fault 1, input terminal S1 (EF1)
0043H
External Fault 2, input terminal S2 (EF2)
0046H
Current Offset Fault (CoF)
0083H
A/D Conversion Error (CPF02)
Drive specification mismatch during Terminal Board or
0087H
Control Board replacement (CPF06)
0089H
EEPROM Serial Communication Fault (CPF08)
008CH
RAM fault (CPF11)
008DH
Flash memory circuit exception (CPF12)
008FH
Control Circuit Fault (CPF14)
0092H
Timing Fault (CPF17)
0093H
Control Circuit Fault (CPF18)
0095H
Hardware fault at power up (CPF20)
0096H
Hardware fault at communication start up (CPF21)
0097H
A/D Conversion Fault (CPF22)
0098H
PWM Feedback Fault (CPF23)
0099H
Drive capacity signal fault (CPF24)
0101H
Option compatibility error (oFA00)
Alarm Code
000BH
External Fault 5, input terminal S5 (EF5)
0014H
MEMOBUS/Modbus Communication Error (CE)
0017H
Motor Overload (oL1)
0018H
Drive Overload (oL2)
0020H
MEMOBUS/Modbus Test Mode Fault (SE)
0039H
External Fault (input terminal S1) (EF1)
003AH
External Fault (input terminal S2) (EF2)
Fault Name
Fault Name
229
C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents