5.2 b: Application
No.
b2-03
Note:
Before starting an uncontrolled rotating motor (e.g., a fan motor driven by windmill effect), use DC Injection to stop the motor before
starting it. Otherwise motor stalling and other faults can occur.
n
b2-04: DC Injection Braking Time at Stop
When the output frequency falls below the minimum output frequency setting E1-09, the drive applies DC injection for the
time set in b2-04. Used to completely stop a motor with high inertia load after ramp down. Increase the setting if the motor
tends to coast by inertia after a stop.
No.
b2-04
84
Name
DC Injection Braking Time at Start
Name
DC Injection Braking Time at Stop
YASKAWA ELECTRIC SIEP C710606 31B YASKAWA AC Drive – J1000 Technical Manual
http://nicontrols.com
Setting Range
0.00 to 10.00 s
Setting Range
0.00 to 10.00 s
Default
0.00 s
Default
0.50 s