B.2 Parameter Table
H2-01
Function
Setting
3D
Speed Search
100 to 102;
104 to 108;
10B, 10E,
H2 Parameter Functions Reversed
110, 117,
Output Switching of 0 to 13D
11A, 11E,
13C, 13D
No.
Name
Sets the input level for terminal A1.
Terminal A1
0: 0 to +10 V (lower limit)
H3-01
Signal Level
1: 0 to +10 V (no lower limit)
Selection
2: 4 to 20 mA
3: 0 to 20 mA
H3-03
Terminal A1 Gain
Sets the level of the input value when 10 V (20 mA) is input at
<1>
Setting
terminal A1.
H3-04
Terminal A1 Bias
Sets the level of the input value when 0 V (0 or 4 mA) is input at
<1>
Setting
terminal A1.
Analog Input Filter
Sets the primary delay filter time constant for terminal A1 or
H3-13
Time Constant
potentiometer (optional). Used for noise filtering.
<1> Parameter can be changed during run.
No.
Name
Selects the data to be output through multi-function analog output
terminal AM.
Multi-Function
Set the desired monitor parameter to the digits available in Uo-
H4-01
Analog Output
oo. For example, enter "103" for U1-03.
Terminal AM
When using this terminal in through mode or when not using it at
all, set "000" or "031".
Multi-Function
H4-02
Sets terminal AM output level when selected monitor is at 100%.
Analog Output
<1>
Maximum output voltage is 10 V.
Terminal AM Gain
Multi-Function
H4-03
Analog Output
Sets terminal AM output level when selected monitor is at 0%.
<1>
Terminal AM Bias
Use H5 Parameters to connect the drive to a MEMOBUS/Modbus network (communication option required).
H5-01
Drive Slave
Selects drive slave number (address) for MEMOBUS/Modbus
<2>
Address
communication. Cycle power for the setting to take effect.
Selects the baud rate for MEMOBUS/Modbus communication.
Cycle power for the setting to take effect.
0 : 1200 bps
Comm. Speed
1 : 2400 bps
H5-02
Selection
2 : 4800 bps
3 : 9600 bps
4 : 19200 bps
5 : 38400 bps
Selects the communication parity for MEMOBUS/Modbus
communication. Cycle power for the setting to take effect.
Comm. Parity
H5-03
0: No parity
Selection
1: Even parity
2: Odd parity
196
H2 Multi-Function Digital Output Settings
Closed: Speed search is being executed
Reverse the output switching of the multi-function output functions. Set the last
two digits of 1oo to reverse the output signal of that specific function
Examples:
Setting "108" reverses the output of "During baseblock", which is setting value
08
Setting "13C" reverses the output of "LOCAL/REMOTE Status", which is setting
"3C"
Description
H3: Analog Input A1
Use H3 parameters to set the analog input terminal A1.
Description
H4: Multi-Function Analog Output AM
Use H4 parameters to configure the multi-function analog output terminal AM.
H5: MEMOBUS/Modbus Communications
YASKAWA ELECTRIC SIEP C710606 31B YASKAWA AC Drive – J1000 Technical Manual
http://nicontrols.com
Description
Range
Def.
0 to 3
0
-999.9 to
100.0
999.9
%
-999.9 to
0.0%
999.9
0.00 to 2.00 0.03 s
Range
Def.
000 to 999
102
-999.9 to
100.0%
999.9
-999.9 to
0.0%
999.9
0 to FF
1F
0 to 5
3
0 to 2
0
Page
107
107
Addr.
Mode
Pg.
Hex
O
410
107
O
411
108
O
412
108
O
41B
110
Addr.
Mode
Pg.
Hex
O
41D
110
S
41E
110
O
41F
110
O
425
214
O
426
214
O
427
214

Hide quick links: