Huawei quidway s7700 Configuration Manual page 368

Smart routing switch
Hide thumbs Also See for quidway s7700:
Table of Contents

Advertisement

Quidway S7700 Smart Routing Switch
Configuration Guide - SPU
1.
2.
3.
4.
5.
6.
7.
8.
9.
Data Preparation
To complete the configuration, you need the following data
l
l
l
l
l
Procedure
Step 1 Check whether interfaces of LPUs are in Up state.
# Log in to MPU A and MPU B to check whether interfaces GE 2/0/13 of LPU A and LPU B
are in Up state. If interfaces GE 2/0/13 of LPU A and LPU B are in Down state, use cables to
connect LPU A and LPU B of the two firewalls.
[MPU] display interface brief
GigabitEthernet2/0/10
0
GigabitEthernet2/0/11
0
GigabitEthernet2/0/12
0
GigabitEthernet2/0/13
0
igabitEthernet2/0/14
0
GigabitEthernet2/0/15
0
GigabitEthernet2/0/16
0
Step 2 Check the service type of the SPUs.
# Log in to SPU A and SPU B to check whether the service type of SPU A and SPU B is the
firewall service in the system view.
<S7700> system-view
[S7700] display service-type
The service type is Firewall!
# If yes, proceed to the next step. If not, change the service type of SPU A and SPU B to the
firewall service, and then restart SPU A and SPU B after the change.
Issue 01 (2011-07-15)
Check whether interfaces of LPUs are in Up state.
Check the service type of the SPUs.
Configure interfaces of the LPUs.
Configure a TCP link.
Configure interfaces of SPUs.
Configure VRRP.
Configure the channel between SPU A and SPU B.
Check whether VRRP negotiation is correct and whether the channel between SPU A and
SPU B is set up successfully.
Save the configuration.
GE interfaces, VLAN IDs, and bound Eth-Trunks of LPU A and LPU B
GE interfaces, VLAN IDs, and bound Eth-Trunks of MPU A and MPU B
XGE interfaces, IP addresses, bound Eth-Trunks, and dot1q values of SPU A
XGE interfaces, IP addresses, bound Eth-Trunks, and dot1q values of SPU B
ID and virtual IP address of the VRRP backup group and priorities of SPU A and SPU B
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7 Dual-System HSB Configuration
(Figure 7-3
up
up
0%
up
up
0%
down
down
0%
up
up
0%
down
down
0%
down
down
0%
down
down
0%
shows the detailed data):
0%
0
0%
0
0%
0
0%
0
0%
0
0%
0
0%
0
357

Advertisement

Table of Contents
loading

Table of Contents