TROUBLESHOOTING
D While operating D-STAR (Continued)
PROBLEM
The simplex operation can-
not be made using the DR
function.
The digital code squelch
(CSQL) does not work.
You don't know how to up-
date the Repeater List.
D While operating GPS Logger
PROBLEM
Position data cannot be re-
ceived.
POSSIBLE CAUSE
• A call sign is programmed in "CALL
SIGN" of the Repeater List.
• Duplex mode (DUP+, DUP–) is set.
• A repeater frequency is programmed.
• The wrong digital code is set.
POSSIBLE CAUSE
• "External GPS" is selected in the GPS
Set item on the Menu screen, but an ex-
ternal GPS receiver is not connected.
• "OFF" or "Manual" is selected in the
GPS Set item on the Menu screen.
• A GPS signal was not received.
SOLUTION
• Delete the Call sign in "CALL SIGN"
setting of the Repeater List.
• Select "OFF" in "DUP" setting of the
Repeater List.
• Set a simplex frequency.
• Set the correct digital code.
• See "Updating the Repeater List" to
check.
SOLUTION
• Connect an external GPS receiver.
• Select either "Internal GPS" or "Exter-
nal GPS" in the GPS Set item on the
Menu screen.
• Move until the GPS signal is received.
20-2
REF.
p. 9-28
p. 9-31
p. 9-30
p. 9-21
p. 8-21
REF.
p. 10-2
p. 16-32

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ID-51A and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Id-51e

Table of Contents