Network load control

7.5.2 Setting the flow control

Select the
Basics:Port Configuration dialog.
In the "Flow Control on" column, you checkmark this port to specify
that flow control is active here. You also activate the global "Flow
Control" switch in the
Switching:Global dialog.
Select the Switching:Global dialog.
With this dialog you can
switch off the flow control at all ports or
switch on the flow control at those ports for which the flow control
is selected in the port configuration table.
124
7.5 Flow control
Basic Configuration L2P
Release 4.2 07/08