10.3

Common technical power data

Feature
Line supply voltage
Output voltage
Input frequency
Minimum cable impedance U
Power factor λ
Pulse frequency
Maximum motor cable length
Possible braking methods
Degree of protection
Ambient temperature
Storage temperature
Relative humidity
Installation altitude
Shock and vibration
Short-circuit current rating
(SCCR)
SINAMICS G120C converter
Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC
Data
3 AC 380 V ... 480 V + 10 % - 20 %
3-ph. 0 V ... line voltage × 0.95 (max.)
47 Hz ... 63 Hz
1 %
K
0.70
4 kHz
The pulse frequency can be increased in 2 kHz steps. A higher pulse frequency reduces
the permissible output current.
Shielded: 50 m
unshielded: 100 m
Shielded: 150 m
unshielded: 225 m
Shielded: 100 m
unshielded: 150 m
25 m (shielded)
DC braking, compound braking, dynamic braking with integrated chopper
IP20, installation in a control cabinet
-10 °C ... +40 °C
Without derating
-10 °C ... +50 °C
Inverter, frame size FSAA
-10 °C ... +55 °C
Inverters, frame sizes FSA ... FSC
with PROFINET interface.
-10 °C ... +60 °C
Inverters, frame sizes FSA ... FSC
with USS, MB, CANopen or
PROFIBUS interface.
-40 °C ... +70 °C (-40 °F ... 158 °F)
< 95 % relative humidity – condensation not permissible
Up to 1000 m above
sea level
Long-term storage in the transport packaging according to Class 1M2 acc. to EN
60721-3-1: 1997
Transport in the transport packaging according to Class 2M3 to EN 60721-3-2: 1997
Vibration in operation according to Class 3M2 acc. to EN 60721-3-3: 1995
40 kA
The actual permissible line voltage depends on
the installation altitude.
Without output reactor or output options for a switching frequency
of 4 kHz
Line voltage < 440 V: With output reactor for a switching frequency
of 4 kHz
Line voltage > 440 V: With output reactor for a switching frequency
of 4 kHz
To satisfy EMC Cat. C2 cable-conducted interference emission for
a 4 kHz switching frequency
At higher installation altitudes, the output power must be re-
duced
Technical data
10.3 Common technical power data
The output power must be
reduced, also see Section:
Temperature and voltage de-
rating (Page 369)
359