Advanced commissioning
6.7 Application-specific functions
6.7.4

Motor holding brake

The motor holding brake holds the motor in position when it is switched off. If the setting is
correct, the motor will produce an electrical holding torque before the inverter opens the
brake. The inverter does not close the motor holding brake until the motor is at a standstill.
Connecting a motor holding brake
You can use any inverter digital output to control the motor holding brake.
If the current or voltage rating of the digital output is not sufficient, then you must control the
motor holding brake through a coupling relay.
U
1
U
2
Figure 6-42
To define which of the digital outputs of the inverter is used to control the motor holding
brake, you must interconnect the corresponding digital output with the brake control signal:
● Digital output DO 0: p0730 = 52.12
● Digital output DO 1: p0731 = 52.12
238
Power supply for the interface relay
Power supply for the motor holding brake
Connect the motor holding brake to digital output DO 0 of the inverter via interface relay
K1.
Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC