Advanced commissioning
6.7 Application-specific functions
6.7.1.1

Changing over the motor standard

You change over the motor standard using p0100. The following applies:
● p0100 = 0: IEC motor (50 Hz, SI units)
● p0100 = 1: NEMA motor (60 Hz, US units)
● p0100 = 2: NEMA motor (60 Hz, SI units)
The parameters listed below are affected by the changeover.
Table 6- 36
P no.
r0206
p0307
p0316
r0333
p0341
p0344
r1969
*) Factory setting
224
Variables affected by changing over the motor standard
Designation
Power Module rated power
Rated motor power
Motor torque constant
Rated motor torque
Motor moment of inertia
Motor weight (for thermal motor type)
Speed_cont_opt moment of inertia determined
0*
)
kW
kW
Nm/A
Nm
kgm
kg
kgm
Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC
Unit for p0100 =
1
HP
kW
HP
kW
lbf ft/A
Nm/A
lbf ft
Nm
lb ft
kgm
2
2
Lb
lb ft
kgm
2
2