02.98

Technical data

Technical data, supply infeed modules
Table 3-2
Technical data, supply infeed modules, internal cooling
Des.
for supply in-
Pv
Monitoring module
Monitoring module
70/–/70
Pulsed resistor
Pulsed resistor
310/–/10
5/6.5/10
UE module, 5/10 kW
UE module 5/10 kW
270/–/70
10/13/25
UE module, 10/25 kW
UE module 10/25 kW
450/–/150
28/36/50
UE module, 28/50 kW
UE module 28/50 kW
250/–/250
16/21/35
I/R module 16/21 kW
I/R module, 16/21 kW
320/–/320
36/47/70
I/R module 36/47 kW
I/R module, 36/47 kW
585/–/585
55/71/91
I/R module, 55/71 kW
I/R module 55/71 kW
745/–/745
55/71/91
I/R module, 55/71 kW pipe
connection
–/630/115
I/R module, 80/104 kW
80/104/131
pipe connection or radial
i e connection or radial
1280/1090/190
fan
I/R module, 120/156 kW
120/156/175
pipe connection or
i e connection or
1950/1660/290
1)
radial fan
1)
If pipe cooling is not used, only Pv
2)
If the internal pulsed resistor is shutdown, for internal cooling, the only power loss is Pv
3)
The motor braking energy is converted into heat in the integrted pulsed resistor; a heat barrier may be
required, refer to p. 1-34
4)
The 1st number is for cable lugs, the 2nd number is valid for finely–stranded conductors
without connector sleeve.
5)
It can be used: a) 0.3/25 kW b) 2 x 0.3/25 kW c) 1.5/25 kW d) 2 x 1.5/25 kW
Siemens AG 1998 All Rights reserved
SIMODRIVE 611 (PJ)
3.2.1 Technical data, supply infeed modules
P
/P
/P
P
/P
/P
n
s6
max
n
s6
max
for regenera-
feed [kW]
tive feedback.
For UE with
internal pul-
sed resistor
[kW]
[kW]
Power los-
1)
ses[W]
/Pv
/Pv-
tot.
ext
int
3)
0.3/–/25
(450 V DC)
/310
2)
3)
0.2/–/10
(450 V DC)
/270
2)
3)
0.3/–/25
(450 V DC)
/450
2)
5)
0.3/–/25
(450 V DC)
16/21/35
16/21/35
36/47/70
36/47/70
55/71/91
55/71/91
55/71/91
55/71/91
80/104/131
80/104/131
120/156/175
120/156/175
has to be taken into account.
tot
6SN1197–0AA00 02.98 Edition
Input current
Max.
Module
[A]
cross–sec-
4)
for 3–ph.
tion
2
[mm
]
400 V AC,
600 V DC
P
/P
/P
n
s6
max
Output cur-
Weight
rent [A]
50
16/10
16/10
5
50
6/4
6/4
5
11.3/14.7/22.6
50
6/4
6/4
9.3/12/18.6
6.5
(540 V DC)
21.8/28.5/54.5
100
16/10
16/10
18.5/24/46.5
9.5
(540 V DC)
58.5/75/104.5
200
50
50
52/67/93
13.5
(540 V DC)
27/35.5/59
100
16/10
16/10
26.5/35/58
10.5
60.5/79/117.5
200
50
50
60/78/116
15.5
92.5/119/153
300
95 or
2 x 35
91/118/151
26
92.5/119/153
300
95 or
2 x 35
91/118/151
26
134/175/220
300
95 or
2 x 35
133/173/218
26
202/262/294
300
150 or
2 x 50
200/260/291
28
Energy of
width
the pulsed
[mm]
resistor
for 1 x bra-
king ope-
ration
[kg]
int.: E
=
max
7.5 kWs
ext.: E
=
max
180 kWs
int.: E
=
max
13.5 kWs
int.: E
=
max
7.5 kWs
External 1:
E
=
max
7.5 kWs
External 2:
E
=
max
180 kWs
.
int