6.5.2.2
Friction characteristic
Function
In many applications, e.g. applications with geared motors or belt conveyors, the frictional
torque of the load is not negligible.
The inverter provides the possibility of precontrolling the torque setpoint, bypassing the
speed controller. The precontrol reduces overshooting of the speed after speed changes.
Figure 6-34
The inverter calculates the current frictional torque from a friction characteristic with 10
intermediate points.
Figure 6-35
The intermediate points of the friction characteristic are defined for positive speeds. In the
negative direction of rotation, the inverter uses the intermediate points with a negative sign.
SINAMICS G120C converter
Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC
Precontrol of the speed controller with frictional torque
Friction characteristic
Advanced commissioning
6.5 Motor control
205