Installing
4.8 Connecting the inverter
Default setting 8: "MOP with Basic Safety"
DO 0: p0730, DO 1: p0731
Motorized potentiometer, setpoint after the ramp-function generator: r1050
Speed setpoint (main setpoint): p1070[0] = 1050
Designation in the BOP-2: MoP SAFE
Default setting 9: "Standard I/O with MOP"
DO 0: p0730, DO 1: p0731
Motorized potentiometer, setpoint after the ramp-function generator: r1050
Speed setpoint (main setpoint): p1070[0] = 1050
Designation in the BOP-2: Std MoP
74
AO 0: p0771[0]
AO 0: p0771[0]
Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC
DI 0: r0722.0, ..., DI 5: r0722.5
DI 0: r0722.0, ..., DI 3: r0722.3
SINAMICS G120C converter