Figure 26: Terminal Receptor: Power Input Contacts For Poe Models; Figure 27: Removing A Terminal Block - Advantech eWorx SE500 User Manual

Table of Contents

Advertisement

Figure 26: Terminal Receptor: Power Input Contacts for PoE models

To wire the power inputs:
Make sure the power is not connected to the switch or the power converter before proceeding.
Loosen the screws securing terminal block to the terminal block receptor.
1.
Remove the terminal block from the switch.
2.

Figure 27: Removing a Terminal Block

Insert a small flat-bladed screwdriver in the V1+/V1- wire-clamp screws, and loosen the
3.
screws.
Insert the negative/positive DC wires into the V+/V- terminals of PW1. If setting up power
4.
redundancy, connect PW2 in the same manner.
Tighten the wire-clamp screws to secure the DC wires in place.
5.
50
eWorx SE500 Series Switches
:

Advertisement

Table of Contents
loading

Table of Contents