[D] Reproduction ratio adjustment of the secondary scanning direction
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.  (Adjustment Mode)
(2)
Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
(3)
Press [FAX] to make a copy at the mode of A3 (LD), 100% and standard drawer of the equipment
(Refer to *).
* Perform 08-477 and check the value.
If the value is 0, use the lower drawer.
If the value is 1, use the upper drawer.
(4)
Measure the distance C from 200 mm to 400 mm of the copied image of the ruler.
(5)
Check if the distance C is within the range of 200±0.5 mm.
(6)
If not, use the following procedure to change values and repeat steps (3) to (5) above.
(Adjustment Mode)  (Key in the code [340])  [START]
 (Key in a value (acceptable values: 0 to 255))
 Press the [ENTER] or the [INTERRUPT] button (stored in memory).
 ("100% A" is displayed.)
* The smaller the adjustment value is, the lower the reproduction ratio becomes (0.45 mm/
step).
50
e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
ADJUSTMENT
Copied image of the ruler
100
150
200
Fig. 3-14
3 - 16
04/09
250
300
350
C
Feeding direction