Toshiba e-studio200l Service Handbook page 234

Hide thumbs Also See for e-studio200l:
Table of Contents

Advertisement

Setting mode (08) <e-STUDIO202L/203L/232/233/282/283>
Classifi-
Code
cation
799
General
Forcible end of trial period
800-0
Fuser
Temperature
control lower
limit
(OHP film)
800-1
801-0
Fuser
Temperature
control lower
limit
(Thick paper
1)
801-1
802-0
Fuser
Temperature
control lower
limit
(Thick paper
2)
802-1
803-0
Fuser
Temperature
control lower
limit
(Thick paper
3)
803-1
804-0
Fuser
Temperature
control lower
limit
(Envelope)
804-1
e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
ERROR CODE AND SELF-DIAGNOSTIC MODE
Func-
Items
tion
PRT/
SCN
Center
ALL
thermistor
Side
ALL
thermistor
Center
ALL
thermistor
Side
ALL
thermistor
Center
ALL
thermistor
Side
ALL
thermistor
Center
ALL
thermistor
Side
ALL
thermistor
Center
ALL
thermistor
Side
ALL
thermistor
2 - 198
07/11
Default
<Accept-
RAM
able
value>
-
SYS
[CANCEL]: Cancel
[EXECUTION]: Forc-
ible end
When the "Forcible end
of trial period" is per-
formed, "0" is set in the
code (08-673) to end up
the trial period forcibly.
8
M
0: 130°C
<0-12>
2: 140°C
4: 150°C
6: 160°C
8: 170°C
6
M
10: 180°C
<0-12>
11: 185°C
12: 120°C
8
M
0: 130°C
<0-12>
2: 140°C
4: 150°C
6: 160°C
8: 170°C
6
M
10: 180°C
<0-12>
11: 185°C
12: 120°C
8
M
0: 130°C
<0-12>
2: 140°C
4: 150°C
6: 160°C
8: 170°C
9
M
10: 180°C
<0-12>
11: 185°C
12: 120°C
8
M
0: 130°C
<0-12>
2: 140°C
4: 150°C
6: 160°C
8: 170°C
10
M
10: 180°C
<0-12>
11: 185°C
12: 120°C
8
M
0: 130°C
<0-12>
2: 140°C
4: 150°C
6: 160°C
8: 170°C
10
M
10: 180°C
<0-12>
11: 185°C
12: 120°C
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
Proce-
Contents
dure
3
1: 135°C
4
3: 145°C
5: 155°C
7: 165°C
9: 175°C
4
1: 135°C
4
3: 145°C
5: 155°C
7: 165°C
9: 175°C
4
1: 135°C
4
3: 145°C
5: 155°C
7: 165°C
9: 175°C
4
1: 135°C
4
3: 145°C
5: 155°C
7: 165°C
9: 175°C
4
1: 135°C
4
3: 145°C
5: 155°C
7: 165°C
9: 175°C
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents