Toshiba e-studio200l Service Handbook page 333

Hide thumbs Also See for e-studio200l:
Table of Contents

Advertisement

<Procedure>
(1)
While pressing [0] and [5] simultaneously,
turn the power ON.
(2)
Press [FAX] to make a copy of any image on
a sheet of A3/LD paper.
(3)
Key in [308] and press the [START] button to
move the carriage to the adjustment position.
(4)
Make an adjustment in the order of step 1
and 2.
Step 1
-
In case of A:
Tighten the mirror-3 adjustment screw
(CW).
-
In case of B:
Loosen the mirror-3 adjustment screw
(CCW).
Step 2
-
In case of C:
Tighten the mirror-1 adjustment screw
(CW).
-
In case of D:
Loosen the mirror-1 adjustment screw
(CCW).
(5)
Apply the screw locking agents to the adjust-
ment screws. (2 areas)
Recommended screw lock agent
Manufacturer: Three Bond
Product name: 1401E
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
Adjustment screw for the mirror-3 (Rear)
Fig. 3-10
Adjustment screw
for the mirror-1 (Rear)
Fig. 3-11
e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
3 - 13
3
Carriage-2
Carriage-1
ADJUSTMENT

Hide quick links:

Advertisement

Table of Contents
loading