Setting mode (08) <e-STUDIO202L/203L/232/233/282/283>
Classifi-
Code
cation
521
Fuser
Fuser roller temperature
during printing
(Side thermistor/Envelope)
523
Fuser
Pre-running time for first
printing
(Envelope)
525-0
Fuser
Temperature
drop switching
time setting
525-1
during printing
(Center ther-
525-2
mistor)
525-3
526
Fuser
Pre-running time for first
printing (OHP film)
527-0
Fuser
Temperature
drop switching
time setting
527-1
during printing
(Side ther-
527-2
mistor)
527-3
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
Default
Func-
<Accept-
Items
tion
value>
ALL
<0-14>
ALL
<0-15>
The first
ALL
drop
<0-200>
The sec-
ALL
ond drop
<0-200>
The third
ALL
drop
<0-200>
The fourth
ALL
drop
<0-200>
ALL
<0-15>
The first
ALL
drop
<0-200>
The sec-
ALL
ond drop
<0-200>
The third
ALL
drop
<0-200>
The fourth
ALL
drop
<0-200>
2 - 185
07/11
RAM
Contents
able
9
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
10
M
0: Invalid 1: 1 sec.
2: 2 sec. 3: 3 sec.
4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec.
8: 8 sec. 9: 9 sec.
10: 10 sec.
11: 12 sec.
12: 14 sec.
13: 16 sec.
14: 18 sec.
15: 20 sec.
20
M
This code is valid only
when "20" is set to 08-
535.
38
M
Setting value x 5 sec.:
from 0 to 1,000 sec.
75
M
later
75
M
0
M
0: Invalid 1: 0 sec.
2: 2 sec. 3: 3 sec.
4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec.
8: 8 sec. 9: 9 sec.
10: 10 sec.
11: 12 sec.
12: 14 sec.
13: 16 sec.
14: 18 sec.
15: 20 sec.
20
M
This code is valid only
when "20" is set to 08-
535.
30
M
Setting value x 5 sec.:
from 0 to 1,000 sec.
48
M
later
75
M
e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
ERROR CODE AND SELF-DIAGNOSTIC MODE
Proce-
dure
1
2
1
4
4
4
4
1
4
4
4
4