EG2–242
1MZ–FE ENGINE
–
SFI SYSTEM
(b) Attach the pressure regulator to the delivery pipe.
(c) Check that the pressure regulator rotates smoothly.
NOTICE: If it does not rotate smoothly, the O–ring may
be pinched, so remove the pressure regulator and repeat
steps (a) to (e) above.
(d) Install the pressure regulator with the 2 bolts.
Torque: 8 N–m (80 kgf–cm, 69 in.–lbf)
2. CONNECT FUEL RETURN HOSE TO FUEL PRES–
SURE REGULATOR
NOTICE: Be sure insert the hose up to the stopper and
clip It.
3. CONNECT VACUUM SENSING HOSE TO FUEL
PRESSURE REGULATOR
4. CONNECT NEGATIVE (–) TERMINAL CABLE
TO BATTERY
5. CHECK FOR FUEL LEAKS
(See page EC–228)