Seamless

The selected update is highlighted with pink circle and color.
It is possible to display two C-MAP databases with official (ENC from C-MAP) and non-official
ENC data (C-MAP Professional or C-MAP Prof. Plus) in seamless mode.
Both databases:
ENC from C-MAP (SENC format).
C-MAP World Professional or C-MAP Professional. Plus (SENC format).
have preliminarily to be installed in usual way from "C-MAP" page of "Chart handling"
dialogue.
If both World Professional or C-MAP Professional. Plus are installed, only Professional Plus
database will be used in chart display in seamless mode.
If C-MAP Professional Plus database is not installed then World Professional database will be
used in chart display in seamless mode.
Seamless mode can be switched on in "Special effects" page of "Chart settings" dialogue by
"Full seamless" radio button and switched off by "Seamless off"